CONNECTING TO THE POWER MAINS

The electric range is a heat consumer, the installation and location of which must correspond with local standards in
force.
Three brass bridges are available for connection. 1 bridge is needed for three-phase connection (380
– 415V 3N~). Three bridges are needed for single-phase connection (220 – 240 V ~).

CLAMP PROTECTION

The clamps should be protected by a clamp cover, see additional equipment. Electric shock danger.

IMPORTANT NOTICE

At any electric range disassembly or assembly besides its current use it is necessary to disconnect the appliance from
mains and to keep it out of service.
In installation of the appliance, it is necessary to do in the light of its duty chiefly the following:
• Verification of the correctness of mains connection.
• A check on the duty of heaters, control and governing elements.
• Presentation to the client of all functions of the appliance and familiarisation with its service and maintenance.
NOTICE
The electric range is a Class I appliance according to the electric current injury prevention degree and must be
interconnected with the mains protective conductor.
A device disconnecting the appliance from mains, whose off
contacts of all poles are in a minimum distance of 3 mm, must
be built in the stable electrical energy distribution before the
appliance.
Solely an authorised, skilled person may install the range. The
authorised person is obliged to set the range cooking plate in
horizontal position, to connect it to the mains and to check up
on its duty. Installation of the range must be confirmed in the
certificate of warranty.
There is the recommended three-phase connection of the
range with the aid of an H05VV-F5G1,5 type connecting cord
(previously CGLG 5Cx1,5), (circuit breaker 3x16 A).
For single-phase connection use an H05VV-F3G4 (previously
GGLG 3Cx4), (circuit breaker 32 - 40 A to the type).
It is necessary to brace the conductor ends with pressed
terminals against fraying.
After bracing the conductor ends beneath the terminal board
screw heads place a cord in the terminal board and secure it
by a clip against tearing. Eventually close the terminal board
cover.