Cameron WKM SAF-T-SEAL M Installation, Operation And Maintenance Manual

Cameron WKM SAF-T-SEAL M Installation, Operation And Maintenance Manual

Api 6d gate valves

Advertisement

Quick Links

Installation, Operation and Maintenance Manual
®
WKM
SAF-T-SEAL
API 6D GATE VALVES
Installation, Operation and Maintenance Manual
®
P R O C E S S V A L V E S
WKM
IOM-WKM-GATE-SAF-T-SEAL
®

Advertisement

Table of Contents
loading

Summary of Contents for Cameron WKM SAF-T-SEAL M

  • Page 1 P R O C E S S V A L V E S Installation, Operation and Maintenance Manual ® ® SAF-T-SEAL API 6D GATE VALVES ® Installation, Operation and Maintenance Manual IOM-WKM-GATE-SAF-T-SEAL...
  • Page 2: Table Of Contents

    Lubricating Handwheel and Operator Assembly....13 Lubricating Seats ............13 Recommended Lubricants and Sealants ......14 Maintaining Vee-Packing ..........16 Trouble Shooting Chart ..........17 © Cameron’s Valves & Measurement Group Printed in Canada 07/09-ION-2M IOM-WKM-GATE-SAF-T-SEAL Rev. 1 07/09 Installation, Operation and Maintenance Manual...
  • Page 3: Inch - 4 Inch Model M

    P R O C E S S V A L V E S Valve Details - 2 inch - 4 inch Model M PLUG INDICATOR ROD STEM PROTECTOR DOWNSTOP BEARING HOUSING THRUST BEARINGS STEM NUT PACKING RETAINER LOCK NUT PACKING RETAINER NUT PACKING SET BONNET PACKING FITTING...
  • Page 4: Inch - 12 Inch Model C3/C6

    P R O C E S S V A L V E S Valve Details - 6 inch - 12 inch Class 300-900 Model C6B PACKING ADAPTER PACKING RING INDICATOR ROD LANTERN RING ROD WIPER SLS SEAL RING PEDESTAL STEM PROTECTOR PACKING ARRANGEMENT BEVEL GEAR OPERATOR YOKE TUBE...
  • Page 5: Inch - 12 Inch Class 300 - 900 Model C6B

    P R O C E S S V A L V E S Valve Details - 6 inch - 12 inch Model C3/C6 INDICATOR ROD STEM PROTECTOR BEARING HOUSING STEM NUT O-RING STEM NUT THRUST BEARINGS BEARING HOUSING GASKET STEM YOKE TUBE PACKING PLUG PACKING...
  • Page 6: 14 Inch - 36 Inch Class 300 - 900 Model C2B/C2C

    P R O C E S S V A L V E S Valve Details - 6 inch - 12 inch Class 1500 - 2500 14 inch - 36 inch Class 300 - 900 Model C2B/C2C INDICATOR ROD GROMMET STEM PROTECTOR SPLIT COLLAR ASSEMBLY GEAR HOUSING PINION...
  • Page 7: Scope

    P R O C E S S V A L V E S Scope This manual covers all bolted bonnet Saf-T-Seal Saf-T-Seal valves do not depend on lubricant gate valves. Drawings, shown are typical. for a seal in normal operation. However, The design of specific valves may vary slightly lubricants/sealants can be injected to promote from the drawings.
  • Page 8: Storage

    These measures will provide protection for If long-term storage is required, the valve should be approximately six months. The following conditioned by the following Cameron procedure care should be taken when storing valves: X-150771-01. Ensure adequate end connection covers are in place. Request a copy of X-150771-01 1.
  • Page 9: Hydrostatic Testing

    P R O C E S S V A L V E S Installation Continued 1. Use solvent to clean grease or rust 4. Weld with the gate in "Full Open" position. inhibitor from the gate and/or bore of the valve. 5.
  • Page 10: Operation

    CLOCKWISE until a necessary, obtain the part number from the unit's stop is felt. The indicator rod at the top of the nameplate and contact Cameron's Valves & valve will move down (towards the valve bore), Measurement group or the nearest as the handwheel is turned CLOCKWISE.
  • Page 11: Routine Maintenance

    P R O C E S S V A L V E S Routine Maintenance The following outlines the minimum scheduled Operate the valve once a month, if practical. maintenance required for WKM Saf-T-Seal A full open-closed cycle is preferable. Gate Valves to promote trouble-free service Operate a partial cycle as a minimum.
  • Page 12: Low Temperature Precautions

    Carefully remove the safety cap of the lower Low Temperature Precautions drain grease fitting. Contact your local Cameron's Valves & Measurement group Prior to exposure to freezing temperatures it representative for further assistance, if is highly recommended the valve be drained.
  • Page 13 P R O C E S S V A L V E S Low Temperature Precautions Continued Volume of Anti-freeze (Ethylene Glycol) to Prevent Freezing Minimum Expected Temperature Valve 18°F (-8°C) 13°F (-11°C) 7°F (-14°C) -8°F (-22°C) -28°F (-33°C) (Percent Anti-freeze) (18%) (23%) (28%)
  • Page 14 P R O C E S S V A L V E S Low Temperature Precautions Continued Volume of Anti-freeze (Ethylene Glycol) to Prevent Freezing Minimum Expected Temperature Valve 18°F (-8°C) 13°F (-11°C) 7°F (-14°C) -8°F (-22°C) -28°F (-33°C) (Percent Anti-freeze) (18%) (23%) (28%)
  • Page 15: Lubricating Handwheel And Operator Assembly

    If this is not possible, contact your local as Handwheel Operated Valves above. Cameron Valves & Measurement group representative for low temperature sealant Motor Operated Valves- recommendations.
  • Page 16: Recommended Lubricants And Sealants

    P R O C E S S V A L V E S Lubricating Handwheel and Operator Assembly Continued Note: Grease guns can develop pressures far WARNING: Back up the seat grease fitting in excess of the valve working pressure. using a wrench so only the safety cap will Use only grease guns, which are equipped be removed from the fitting.
  • Page 17 P R O C E S S V A L V E S Lubricating Handwheel and Operator Assembly Continued PRODUCT MANUFACTURER WKM 1 Cameron Valves & Measurement WKM 58G CAMSERV™ Aftermarket Services WKM 102 8820 Meldrum Ln WKM 103 Houston, TX 77075...
  • Page 18: Maintaining Vee-Packing

    P R O C E S S V A L V E S Maintaining Vee-Packing (If so equipped) - Once a year or more often as required. 1. Valves equipped with Vee Packing may require periodic This might be determined by paint inspection and maintenance to preclude stem leakage.
  • Page 19: Trouble Shooting Chart

    The valve is leaking Ensure that the bonnet nuts are tightened properly. The bonnet seal is leaking. around bonnet to Call CAMERON VALVES & MEASUREMENT group body joint. representative if leakage persists. A restriction is present The gate is not properly aligned HANDWHEEL OR BEVEL GEAR OPERATED in the valve bore.
  • Page 20 P R O C E S S V A L V E S Contact your Cameron’s Valves & Measurement group representative for a Repair Manual ® 3250 Briarpark Drive, Suite 300 Houston, Texas 77042 USA Toll Free 800 323 9160 For the most current contact and location information go to: www.c-a-m.com/valvesandmeasurement...

Table of Contents