Accessing settings – Legend for tables
You can access the installer settings using two different methods.
However, NOT all settings are accessible via both methods. If so,
the corresponding table columns in this chapter are set to N/A (not
applicable).
Method
Accessing settings via the breadcrumb in the
home menu screen or the menu structure.
To enable breadcrumbs, press the
in the home screen.
Accessing settings via the code in the
overview field settings.
See also:
settings" [ 4  23]
"To access the installer
"7.5 Menu structure: Overview installer
7.1.1

To access the most used commands

To change the user permission level
You can change the user permission level as follows:
1 Go to [B]: User profile.
B
User profile
2 Enter the applicable pin code for the user permission
level.
▪ Browse through the list of digits and change the
selected digit.
▪ Move the cursor from left to right.
▪ Confirm the pin code and proceed.
Installer pin code
The Installer pin code is 5678. Additional menu items and
installer settings are now available.
Installer
5678
Advanced user pin code
The Advanced user pin code is 1234. Additional menu items for the
user are now visible.
Advanced user
1234
User pin code
The User pin code is 0000.
User
0000
ETVH16SU18+23E
Daikin Altherma 3 H HT F
4P644729-1E – 2023.10
Column in tables
#
For example: [2.9]
button
Code
For example: [C-07]
settings" [ 4  31]
To access the installer settings
1 Set the user permission level to Installer.
2 Go to [9]: Installer settings.
To modify an overview setting
Example: Modify [1‑01] from 15 to 20.
Most settings can be configured via the menu structure. If for any
reason it is required to change a setting using the overview settings,
then the overview settings can be accessed as follows:
1 Set the user permission level to Installer. See
change the user permission
2 Go to [9.I]: Installer settings > Overview
field settings.
3 Turn the left dial to select the first part of the setting
and confirm by pressing the dial.
00
05
0A
0
01
06
0B
1
02
07
0C
2
03
08
0D
3
04
09
0E
4 Turn the left dial to select the second part of the
setting
00
05
0A
01 15
06
0B
1
02
07
0C
03
08
0D
04
09
0E
5 Turn the right dial to modify the value from 15 to 20.
00
05
0A
01 20
06
0B
1
02
07
0C
03
08
0D
04
09
0E
6 Press the left dial to confirm the new setting.
7 Press the center button to go back to the home
screen.
INFORMATION
When you change the overview settings and you go back
to the home screen, the user interface will show a popup
screen and request to restart the system.
When confirmed, the system will restart and recent
changes will be applied.
7.2

Configuration wizard

After first power ON of the system, the user interface starts a
configuration wizard. Use this wizard to set the most important initial
settings for the unit to run properly. If required, you can afterwards
configure more settings. You can change all these settings via the
menu structure.
Protective functions
The unit is equipped with the following protective functions:
▪ Room antifrost [2-06]
▪ Water pipe freeze prevention [4-04]
▪ Tank disinfection [2-01]
The unit automatically runs the protective functions when necessary.
During installation or service, this behaviour is undesired. Therefore,
the protective functions can be disabled. For more information, see
the Installer reference guide, chapter Configuration.