Daikin Altherma 3 H HT F ETVH16SU18E 6V Series Installation Manual page 42

Table of Contents

Advertisement

11 Technical data
Electrical connection diagram
For more details, please check the unit wiring.
POWER SUPPLY
Only for normal power supply installation
1
5 or 3 core
Unit power supply:
400 V or 230 V + earth
1
Only for preferential kWh rate power supply installation
5 or 3 core
Unit preferential kWh rate power supply:
400 V or 230 V + earth
Normal kWh rate power supply for indoor unit:
2 core
230 V
FIELD SUPPLY
2 core
2
2×0.75
Preferential kWh rate power supply contact
signal
2
Only for low voltage Smart Grid
Smart Grid contact S10S
OPTIONAL PART
2
Only for high voltage Smart Grid
Smart Grid contact K1A
Smart Grid relay K1A
2×0.75
Smart Grid relay K2A
High voltage Smart Grid control supply: 230 V
4 core
FIELD SUPPLY
3
2 core
Safety thermostat Q4L
2×0.75
5 or 4 or 3 core
Backup heater power supply (6/9 kW):
400 V or 230 V + earth
(F1B)
OPTIONAL PART
WLAN module
A20P: J2
communication
Bizone mixing kit
A30P: ST6
communication
FIELD SUPPLY
Power limitation demand input 1
Power limitation demand input 2
Power limitation demand input 3
Power limitation demand input 4
Installation manual
42
STANDARD PART
OUTDOOR UNIT
X1M: L1-L2-L3-N-earth
or L-N-earth
X1M: 1-2-3-earth
4 core
INDOOR UNIT
X1M: 1-2-3-earth
X2M: 5-6
X5M: 9-10
ext. heat source output
2 core
2×0.75
X10M: 1-2
2 core
X10M: 3-4
NO valve: X2M: 21-28
NC valve: X2M: 21-29
X5M: 13
3
X5M: 14
X5M: 13-14
X6M: L1-L2-L3 + earth
or L-N + earth
or L1-L2-L3-N + earth
A11P: X5: 4-5
5 core
A11P: X9: 1-2-3
3 core
A11P: X3: 2-3-4
4
main: X2M: 30-34-35
add: X2M: 30-34a-35a
4
Only for *KRP1AHTA
main: X2M: 30-31-34-35
2 core
add: X2M: 30-31-34a-35a
A8P: X801M: 1-5
signal
2 core
A8P: X801M: 2-5
signal
2 core
A8P: X801M: 3-5
signal
2 core
4
A8P: X801M: 4-5
signal
main & add: X2M: 3-4
Notes:
- In case of signal cable: keep minimum distance to power cables >5 cm
3 core
Drain tube heater
X2M: 1-2 + earth
230 V
A4P: Y1-YC
2 core
Alarm indication
X2M: 7-9
Alarm output
230 V
A4P: X1-X2
2 core
Ext. heat source (e.g. boiler)
Changeover to
signal
A4P: Y2-YC
2 core
Cooling/heating ON/OFF output
X2M: 7-9
Cooling/heating
230 V
ON/OFF output
2 core
Circulation pump for domestic hot water
X2M: 1-2
230 V
2-way valve
2 core
M2S for cooling mode
230 V
2 core
Electricity meter pulse input 1
X5M: 5-6
signal
Only for high voltage Smart Grid
Smart Grid contact K2A
Only for low voltage Smart Grid
Smart Grid contact S11S
2 core
Electricity meter pulse input 2
X5M: 3-4
signal
Smart Grid pulse meter
Only for KRCS01-1 or EKRSCA1
2 core
External thermistor (indoor or outdoor)
X5M: 7-8
signal
External room thermostat / Heat pump convector
Only for EKRTW* (wired room thermostat)
3 core for C/H operation
2 core for H only operation
A2P: X1M: C-com-H
signal
Only for EKRTR* (wireless room thermostat)
5 core for C/H operation
4 core for H only operation
A15P: X1M: H-C-com
X2M: L-N
signal
Only for heat pump convector
main: X2M: 30-35
add: X2M: 30-35a
4 core
A3P
signal
Only for Human Comfort Interface
2 core
2×0.75
X5M: 11-12
A14P: P1-P2 user interface
communication
Only for LAN adapter
2 core
2×0.75
A13P: P1-P2 LAN adapter
communication
FIELD SUPPLY
FIELD SUPPLY
Only for *KRP1HB*
5
5
5
6
6
(main and/or additional zone)
Only for EKRTETS
2 core
(3m included)
R2T External sensor (floor or
7
A2P: X1M: 1-3
ambient)
signal
Only for EKRTR1
7
A2P: X1M: 1-2
Only for EKRTRB
ETVH16SU18+23E
Daikin Altherma 3 H HT F
4P644729-1E – 2023.10
OPTIONAL PART
4D133216C

Advertisement

Table of Contents
loading

Table of Contents