ROUGHING-IN
Reference Value
K-6286T/K-6286T-PNS2/K-6286T-PN2/K-6286T-VES2
Height to floor is decided by bowl
Finished Floor
INSTALLATION
1.
Make sure of h according to dimensions of bowl and then
locate the installation hole of fixing bracket.
wall for appropriate position for fixing bracket, and drill four
holes with diameter of 10mm and depth of 80mm with
churn drilling as shown in illustration, and fill in the holes
with bulge screw and tighten the screw to set the fixing
bracket.
Note:
1. Ensure the fixing bracket to remain level.
2. Adjust the syphon 0~80mm short if necessary.
Syphon
1206284-T01-C
478 3
438 2
Kohler reserves the right to change marked dimensions without prior notice.
Mark on the
h
188
5~45
1.
10mm 80mm
O
1.
2.
-3-
K-6283T
328.5 1
h
0~80mm
Bulge Screw
Gasket
Spring
Nut
UNIT: mm
K-8854T
328.5 1
Fixing Bracket