7. Adjust Inlet Valve
Hoist and reduce the water level in the tank by adjusting
the control pole. Turn the control pole counterclockwise to
lower down the floating box and reduce the water level of
the tank. Turn the control pole clockwise to hoist the
floating box and increase the water level in the tank.
7.
TROUBLE SHOOTING PROCEDURES
TROUBLE SHOOTING PROCEDURES
Symptoms
No water fills in via inlet
valve
No drainage when
pressing the heavy and
slight drainage button
Too high or too low water
level
Leak of the toilet and
squat
1206284-T01-C
Probable Causes
The inlet valve is closed
Floating box of inlet valve is blocked by tank wall
Floating box of inlet valve is block by waste
Wrong installation of adjustable board
Control pole is too long
Water level of the inlet valve is not appropriate
Control pole is too short
Inappropriate adjustment of the overflow pipe
Open inlet valve
Adjust floating box to appropriate position
Wash the floating box with clean water
Reset
Adjust the control pole to appropriate
position
Readjust water level
Adjust the control pole to appropriate
position
Adjust the overflow pipe to appropriate
position
-9-
Adjustment Switch
Recommended Action
Floating Box