Trane 17 Series Installer's Manual page 40

Mini-split inverter system
Hide thumbs Also See for 17 Series:
Table of Contents

Advertisement

17 Series Mini-Split
TEMP.
R min
°C(°F)
(k Ohm)
(k Ohm)
-9(-48.2)
90.49
100.8
-8(-46.4)
85.99
95.68
-7(44.6)
81.75
90.86
-6(-42.8)
77.74
86.31
-5(-41)
73.94
82.01
-4(-39.2)
70.35
77.95
-3(37.4)
66.96
74.11
Resistance at 25°C(77°F): 20 kΩ.
TH3: Outdoor unit discharge pipe sensor
Note: Before measuring resistance, disconnect connectors as shown above.
R(t)
R max
TEMP.
(k Ohm)
°C(°F)
112.1
45(113)
106.3
46(114.8)
100.8
47(116.6)
95.74
48(118.4)
90.88
49(120.2)
86.29
50(122)
81.96
51(123.8)
R min
R(t)
R max
(k Ohm)
(k Ohm)
(k Ohm)
8.217
8.714
9.233
7.908
8.38
8.872
7.612
8.06
8.526
7.328
7.754
8.196
7.057
7.461
7.88
6.797
7.18
7.578
6.548
6.912
7.289
TEMP.
R min
R(t)
°C(°F)
(k Ohm)
(k Ohm)
99(210.2)
1.321
1.373
100(212)
1.284
1.335
101(213.8)
1.245
1.296
102(215.6)
1.209
1.258
103(217.4)
1.173
1.222
104(219.2)
1.139
1.187
105(221)
1.105
1.153
R max
(k Ohm)
1.426
1.387
1.348
1.309
1.272
1.236
1.202

Advertisement

Table of Contents
loading

Table of Contents