Download Print this page

Predator 59187 Owner's Manual & Safety Instructions

1800 watt portable generator

Advertisement

Quick Links

Owner's Manual & Safety Instructions
Save This Manual
operating, inspection, maintenance and cleaning procedures. Write the product's serial number in the
back of the manual (or month and year of purchase if product has no number). Keep this manual and the
receipt in a safe and dry place for future reference.
1800 WATT
PORTABLE
GENERATOR
1400 RUNNING WATTS
1800 MAX STARTING WATTS
59187
using a generator indoors can
KiLL yOu in MinuteS.
Generator exhaust contains
carbon monoxide. this is a poison
you cannot see or smell.
neVer use inside
a home or garage,
eVen iF doors and
windows are open.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1‑888‑866‑5797 as soon as possible.
©
Copyright
2023 by Harbor Freight Tools
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Keep this manual for the safety warnings and precautions, assembly,
Only use OutSiDe
and far away from
windows, doors,
and vents.
®
. All rights reserved.
9 9
9 9
G A
G A
S O
S O
L IN
L IN
c c
c c
E
E
E N
E N
G IN
G IN
E
E
Visit our website at: http://www.harborfreight.com
email our technical support at: productsupport@harborfreight.com
email our engine support at: predator@harborfreight.com
Do not use in
trailers, truck
beds, or tents.
read this material before using this product.
Failure to do so can result in serious injury.
SaVe tHiS ManuaL.
DanGer
use at least 20 feet away from
people, animals, and structures
with exhaust pointed away.
20'
20'
20'
24a
20'
20'

Advertisement

loading

Summary of Contents for Predator 59187

  • Page 1 G IN G IN Visit our website at: http://www.harborfreight.com email our technical support at: productsupport@harborfreight.com 59187 email our engine support at: predator@harborfreight.com DanGer Do not use in use at least 20 feet away from using a generator indoors can trailers, truck people, animals, and structures KiLL yOu in MinuteS.
  • Page 2 10. Use only lubricants and fuel recommended in this manual. Page 2 For technical questions, please call 1-888-866-5797. 59187...
  • Page 3 10. Fire Hazard! Do not fill gas tank while engine is running. Do not operate if gasoline has been spilled. Clean spilled gasoline before starting engine. Do not operate near pilot light or open flame. 59187 For technical questions, please call 1-888-866-5797. Page 3...
  • Page 4 Store oil rags in above 85 dBA is hazardous to hearing. Always a bottom‑ventilated, covered, metal container. wear ear protection when operating or working around the gas engine while it is operating. Page 4 For technical questions, please call 1-888-866-5797. 59187...
  • Page 5 14 AWG 12 AWG 10 AWG 2400 12 AWG 10 AWG 3000 12 AWG 10 AWG 8 AWG 3600 10 AWG 8 AWG 4200 8 AWG 6 AWG 4800 6 AWG 59187 For technical questions, please call 1-888-866-5797. Page 5...
  • Page 6 2. Even used batteries may cause severe injury or death. SaVe tHeSe inStructiOnS. Page 6 For technical questions, please call 1-888-866-5797. 59187...
  • Page 7 Breaker Filter Ground terminal L IN L IN G IN G IN Starting Volt Meter Handle Dc circuit Breaker Dc receptacle cO Sensor Light Low Oil alert engine Switch 59187 For technical questions, please call 1-888-866-5797. Page 7...
  • Page 8 Sensitive electronic equipment should be operated on approved inverter‑type generators or pure sine wave generators. Wheel Kit, #68531 (sold separately) can be used with this Generator. Page 8 For technical questions, please call 1-888-866-5797. 59187...
  • Page 9 The portable generator Neutral conductor is isolated from the frame and from the AC receptacle ground pin. Electrical devices that require a connection between one conductor pin and the grounded receptacle pin may not function properly. 59187 For technical questions, please call 1-888-866-5797. Page 9...
  • Page 10 High altitude Kit parts List - a part Description Main Jet 3000‑6000 ft. Bolt Seal Main Jet 6000‑8000 ft. Bolt Seal Fuel Cup Seal Bolt Solenoid Seal Solenoid Seal Not present on some Solenoid Generators Screws Page 10 For technical questions, please call 1-888-866-5797. 59187...
  • Page 11 (The SAE Viscosity Grade chart on page 18 in the Service section shows other viscosities to use in different average temperatures.) 6. Thread the dipstick back in clockwise. 59187 For technical questions, please call 1-888-866-5797. Page 11...
  • Page 12 The break‑in period will last about 25 maintenance follows the schedule explained hours of use. DO NOT exceed 75% of the in the MAINTENANCE section. Generator’s rated capacity during this period. Page 12 For technical questions, please call 1-888-866-5797. 59187...
  • Page 13 Monoxide sensor must only be serviced by qualified technician to restore it to original settings. Do not modify or tamper with the carbon Monoxide sensor. not following these instructions can result in death or serious injury due to carbon Monoxide sensor malfunction. 59187 For technical questions, please call 1-888-866-5797. Page 13...
  • Page 14 1. Make sure that ALL circuit breakers are reset over outlets: before starting the Generator again. 2. Adjust the plugs so the loads are shared across outlet circuits. to achieve rated output from the Generator, distribute loads over outlets. Page 14 For technical questions, please call 1-888-866-5797. 59187...
  • Page 15 For most lights or heaters: Watts Watts there are no additional start‑up watts. Central AC ‑ 10,000 BTU 1500 1500 Furnace Fan ‑ 1/2 HP 1400 Space Heater 1800 Window AC ‑ 10,000 BTU 1200 59187 For technical questions, please call 1-888-866-5797. Page 15...
  • Page 16 Stopping the engine under normal conditions 1. Before turning off the Engine, turn off all electrical loads, then unplug them. 2. Turn the Engine Switch off. 3. Close the Fuel Valve. Page 16 For technical questions, please call 1-888-866-5797. 59187...
  • Page 17 4. Clean carbon build‑up from combustion chamber Replace fuel line if necessary Service more frequently when used in dusty areas. These items should be serviced by a qualified technician. 59187 For technical questions, please call 1-888-866-5797. Page 17...
  • Page 18 In a well‑ventilated area away from bystanders, use pressurized air to blow dust out of the air filter. If this does not get the filter clean, replace it. Page 18 For technical questions, please call 1-888-866-5797. 59187...
  • Page 19 Drain Bolt from the bottom of the Carburetor Bowl, allowing the fuel to drain completely. Replace the Drain Bolt after draining. WarninG! to prevent serious injury and fire, close the Fuel Valve before draining the carburetor. 59187 For technical questions, please call 1-888-866-5797. Page 19...
  • Page 20 2. Engine mounted on slope, 2. Operate engine on level surface. triggering low oil shutdown. Check engine oil level. Follow all safety precautions whenever diagnosing or servicing the equipment or engine. Page 20 For technical questions, please call 1-888-866-5797. 59187...
  • Page 21 2. Rated load capacity exceeded. 2. Lower the number of items plugged into the Generator to stay within the rated capacity, or use a more powerful generator. 59187 For technical questions, please call 1-888-866-5797. Page 21...
  • Page 22 If product has no serial number, record month and year of purchase instead. note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Specify UPC 193175462381 when ordering parts. Page 22 For technical questions, please call 1-888-866-5797. 59187...
  • Page 23 Diagram 59187 For technical questions, please call 1-888-866-5797. Page 23...
  • Page 24 140 Sleeve, Fuel Tank Rubber Head Screw 103 Cover, Motor Front End 141 Bush 121 Carbon Monoxide Alarm Hex Socket Flange, 142 Jacket, Rubber 122 Nut with Flange Face Bolt 143 Band Page 24 For technical questions, please call 1-888-866-5797. 59187...
  • Page 25 Generator Frame Diagram 59187 For technical questions, please call 1-888-866-5797. Page 25...
  • Page 26 (2) year term of this warranty at no cost to you, including diagnosis, parts and labor. This warranty applies to the original purchaser and any subsequent owner within the two year warranty period. Page 26 For technical questions, please call 1-888-866-5797. 59187...
  • Page 27 The nearest Harbor Freight Tools retail store can be found on the internet at http://www.harborfreight.com. 59187 For technical questions, please call 1-888-866-5797.
  • Page 28 26677 agoura road • calabasas, ca 91302 • 1-888-866-5797...