Download Print this page

Predator 59188 Owner's Manual & Safety Instructions

Super quiet inverter generator, 7600 running watts, 9500 max starting watts
Hide thumbs Also See for 59188:

Advertisement

Quick Links

Owner's Manual & Safety Instructions
Save This Manual
operating, inspection, maintenance and cleaning procedures. Write the product's serial number in the
back of the manual (or month and year of purchase if product has no number). Keep this manual and the
receipt in a safe and dry place for future reference.
SUPER QUIET
INVERTER
GENERATOR
7600 RUNNING WATTS
9500 MAX STARTING WATTS
Email our technical support at: productsupport@harborfreight.com
Email our engine support at: predator@harborfreight.com
Using a generator indoors CAN
KILL YOU IN MINUTES.
Generator exhaust contains
carbon monoxide. This is a poison
you cannot see or smell.
NEVER use inside
a home or garage,
EVEN IF doors and
windows are open.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
©
Copyright
2021 by Harbor Freight Tools
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Keep this manual for the safety warnings and precautions, assembly,
Visit our website at: http://www.harborfreight.com
Only use OUTSIDE
and far away from
windows, doors,
and vents.
®
. All rights reserved.
Do not use in
trailers, truck
beds, or tents.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
59188
 DANGER
Use at least 20 feet away from
people, animals, and structures
with exhaust pointed away.
20'
20'
20'
22g
20'
20'

Advertisement

loading
Need help?

Need help?

Do you have a question about the 59188 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Predator 59188

  • Page 1 7600 RUNNING WATTS 9500 MAX STARTING WATTS Visit our website at: http://www.harborfreight.com Email our technical support at: productsupport@harborfreight.com 59188 Email our engine support at: predator@harborfreight.com  DANGER Do not use in Use at least 20 feet away from Using a generator indoors CAN...
  • Page 2 The emissions control system for this Engine is warranted for standards set by the U.S. Environmental Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information, refer to the last pages of this manual. ITEM 59188 Page 2 For technical questions, please call 1-888-866-5797.
  • Page 3 It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. SAVE THESE INSTRUCTIONS ITEM 59188 For technical questions, please call 1-888-866-5797. Page 3...
  • Page 4 The Carbon Monoxide sensor is an additional layer of protection only. Do not use the Generator in any area or situation that will allow carbon monoxide to accumulate. ITEM 59188 Page 4 For technical questions, please call 1-888-866-5797.
  • Page 5 37. Do not operate the equipment with known leaks in the engine’s fuel system. 21. Secure the generator on transport vehicles to prevent it from rolling, slipping, and tilting. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 5...
  • Page 6 5. Do not use a Parallel Kit that is together using a Parallel Kit. attached to only one Generator. 3. Connect Parallel Kit only to terminals marked “Parallel Outlets” on the front of the Generator. ITEM 59188 Page 6 For technical questions, please call 1-888-866-5797.
  • Page 7 5. Wipe up any spilled fuel and allow excess dust mask/respirator during service. to evaporate before starting engine. To prevent FIRE, do not start the engine while the smell of fuel hangs in the air. SAVE THESE INSTRUCTIONS. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 7...
  • Page 8 4. Locate the black and red battery cables. If battery needs charging during storage, make sure to use a proper lead acid charger (not provided). Unplug charger when battery is fully charged. ITEM 59188 Page 8 For technical questions, please call 1-888-866-5797.
  • Page 9 WARNING! TO pREVENT SERIOUS INJURY: Follow parallel Kit instructions for connection and use of a parallel Kit (parallel Kit and instructions sold separately). Generator must be in 120V/240V mode for parallel function. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 9...
  • Page 10 10% ethanol (E10). Do not use E85 ethanol. Add fuel To prevent FIRE, do not start the engine stabilizer to the gasoline or the Warranty is VOID. while the smell of fuel hangs in the air. ITEM 59188 Page 10 For technical questions, please call 1-888-866-5797.
  • Page 11 Note: Moving the Combination Switch START too fast could stall the Engine. CHOKE IMpORTANT: Allow the Engine to run at no load for five minutes after each start-up so that the Engine can stabilize. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 11...
  • Page 12 Carbon Monoxide sensor must only be serviced by qualified technician to restore it to original settings. Do not modify or tamper with the Carbon Monoxide sensor. Not following these instructions can result in death or serious injury due to Carbon Monoxide sensor malfunction. ITEM 59188 Page 12 For technical questions, please call 1-888-866-5797.
  • Page 13 IMpORTANT! Failure to connect and operate appliances, tools, and equipment in this sequence can cause damage to the Generator, appliances, tools, and equipment and will void the Warranty of this Generator. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 13...
  • Page 14 120V (3-wire) adaptor cord. Exceeding this may cause overload. 240V Cord Connected to L14-30 Receptacle: The 240V cord will draw full wattage from both circuits. If further loads are possible, distribute them across receptacles. ITEM 59188 Page 14 For technical questions, please call 1-888-866-5797.
  • Page 15 Central AC - 10,000 BTU 1500 1500 Furnace Fan - 1/2 HP 1400 For most lights or heaters: Space Heater 1800 there are no additional start-up watts. Window AC - 10,000 BTU 1200 ITEM 59188 For technical questions, please call 1-888-866-5797. Page 15...
  • Page 16 Generator. Then, turn the tripped Circuit Breaker to ON and re-attach loads gradually. Note: For push-type Circuit Breakers allow a few minutes for cool-down before restarting. ITEM 59188 Page 16 For technical questions, please call 1-888-866-5797.
  • Page 17 Generator. If the Economy Switch is ON, turn it to the OFF position. STORAGE Combination Switch 2. Turn the Combination Switch OFF. STORAGE START CHOKE START CHOKE START 3. After engine stops, turn Engine Switch to OFF. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 17...
  • Page 18 4. Clean carbon build-up from combustion chamber – Replace fuel line if necessary Service more frequently when used in dusty areas. These items should be serviced by a qualified technician. ITEM 59188 Page 18 For technical questions, please call 1-888-866-5797.
  • Page 19 SAE 10W-30 oil is recommended for general use. Note: Make sure Generator is level when adding oil to prevent overfilling which could cause engine damage. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 19...
  • Page 20 2. Disconnect Spark Plug Cap from end of plug. Panel on the left side of the Generator. Clean out debris from around Spark Plug. Spark plug Access Spark panel plug ITEM 59188 Page 20 For technical questions, please call 1-888-866-5797.
  • Page 21 Drain Bolt from the bottom of the Carburetor Bowl, allowing the fuel to drain completely. Replace the Drain Bolt after draining. WARNING! To prevent serious injury and fire, close the Fuel Valve before draining the Carburetor. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 21...
  • Page 22 SPARK ARRESTOR RELATED: SPARK ARRESTOR RELATED: 1. Spark Arrestor clogged with soot. 1. Clean and replace Spark Arrestor. Follow all safety precautions whenever diagnosing or servicing the generator or engine. ITEM 59188 Page 22 For technical questions, please call 1-888-866-5797.
  • Page 23 2. Turn off and unplug device, reset Circuit Breaker, plug in device and turn on. 3. Product needs service. 3. Have product repaired. Follow all safety precautions whenever diagnosing or servicing the generator or engine. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 23...
  • Page 24 2. Lower the number of items plugged into the generator to stay within the rated capacity, or use a more powerful generator. Follow all safety precautions whenever diagnosing or servicing the generator or engine. ITEM 59188 Page 24 For technical questions, please call 1-888-866-5797.
  • Page 25 Note: If product has no serial number, record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Specify UPC 193175459091 when ordering parts. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 25...
  • Page 26 48 Handle Pipe Assembly 100 Plug 49 Hex Flange Bolts 101 Insulation Sleeve 50 Right Plate 102 Rubber Plug 51 Plug 103 Air Filter Support 52 Right Side Window Panel Assembly ITEM 59188 Page 26 For technical questions, please call 1-888-866-5797.
  • Page 27 Assembly Diagram - Generator 10 11 ITEM 59188 For technical questions, please call 1-888-866-5797. Page 27...
  • Page 28 93A Endcover 47A Hex Flange Bolt M12x1.5 94A Alternator Cover Plug When ordering replacement parts from this list, the “A” suffix must be included in order to receive the correct part. ITEM 59188 Page 28 For technical questions, please call 1-888-866-5797.
  • Page 29 Assembly Diagram A - Engine ITEM 59188 For technical questions, please call 1-888-866-5797. Page 29...
  • Page 30 As the small off-road engine/equipment owner, you should however be aware that HFT may deny you warranty coverage if your (equipment type or small off-road) engine or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifications. ITEM 59188 Page 30 For technical questions, please call 1-888-866-5797.
  • Page 31 11. HFT issuing the warranty shall provide any documents that describe that warranty procedures or policies within five working days of request by the Executive Officer. ITEM 59188 For technical questions, please call 1-888-866-5797. Page 31...
  • Page 32 7. Particulate Controls equipment written instructions for the maintenance and a. Traps, filters, precipitators, and any use of the engine/equipment by the owner. other device used to capture particulate emissions. ITEM 59188 Page 32 For technical questions, please call 1-888-866-5797.
  • Page 33 ITEM 59188 For technical questions, please call 1-888-866-5797. Page 33...
  • Page 34 ITEM 59188 Page 34 For technical questions, please call 1-888-866-5797.
  • Page 35 ITEM 59188 For technical questions, please call 1-888-866-5797. Page 35...
  • Page 36 26677 Agoura Road • Calabasas, CA 91302 • 1-888-866-5797...

This manual is also suitable for:

71365