Starting the engine
1. To start a cold engine, move the Choke to the START position.
To restart a warm engine, leave the Choke in the RUN position.
2. Open the Fuel Valve.
3. Turn the Engine Switch to ON.
4. Grip the Starter Handle of the Engine loosely and
pull it slowly several times to allow the gasoline
to flow into the Engine's carburetor. Then pull
the Starter Handle gently until resistance is felt.
Allow Cable to retract fully and then pull it quickly.
Repeat until the engine starts. Note: Do not let
the Starter Handle snap back against the engine.
Hold it as it recoils so it doesn't hit the engine.
note: If engine does not start, check engine oil level.
Engine will not start with low or no engine oil.
5. Allow the Engine to run for several seconds. Then, if the Choke lever is in the
START position, move the Choke Lever very slowly to its RUN position.
note: Moving the Choke Lever too
fast could stall the engine.
iMpOrtant: Allow the engine to run at no load for five minutes with no
load after each start‑up so that the engine can stabilize.
carBOn MOnOXiDe SHutOFF
DanGer! tO preVent SeriOuS inJury anD DeatH FrOM carBOn MOnOXiDe inHaLatiOn:
the carbon Monoxide sensor is an additional layer of protection only. Do not use the
Generator in any area or situation that will allow carbon monoxide to accumulate.
• FLASHING RED LIGHT:
Dangerous levels of carbon monoxide gas have
built up and generator will shutoff.
Leave immediately until area has aired
out. Move Generator to well‑ventilated
area before operation.
carbon Monoxide sensor must only be serviced by qualified technician to restore it to original
settings. Do not modify or tamper with the carbon Monoxide sensor. not following these
instructions can result in death or serious injury due to carbon Monoxide sensor malfunction.
59187
For technical questions, please call 1-888-866-5797.
• FLASHING YELLOW LIGHT:
Carbon monoxide sensor malfunction.
Sensor needs service. Do not use the Generator
until the sensor is working properly. For
technical questions, please call 1‑888‑866‑5797.
NOTE: Yellow light flashes once
after starting to indicate passing self‑
check and is functioning normally.
i