Predator 59205 Owner's Manual & Safety Instructions

Predator 59205 Owner's Manual & Safety Instructions

6500 watt
Hide thumbs Also See for 59205:

Advertisement

Quick Links

Owner's Manual & Safety Instructions
Save This Manual
operating, inspection, maintenance and cleaning procedures. Write the product's serial number in the
back of the manual (or month and year of purchase if product has no number). Keep this manual and the
receipt in a safe and dry place for future reference.
Using a generator indoors CAN
KILL YOU IN MINUTES.
Generator exhaust contains
carbon monoxide. This is a poison
you cannot see or smell.
NEVER use inside
a home or garage,
EVEN IF doors and
windows are open.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
©
Copyright
2022 by Harbor Freight Tools
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Keep this manual for the safety warnings and precautions, assembly,
Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
Email our engine support at: predator@harborfreight.com
Only use OUTSIDE
and far away from
windows, doors,
and vents.
®
. All rights reserved.
Do not use in
trailers, truck
beds, or tents.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
DANGER
Use at least 20 feet away from
people, animals, and structures
with exhaust pointed away.
20'
20'
20'
22g
20'
20'

Advertisement

Table of Contents
loading

Summary of Contents for Predator 59205

  • Page 1 (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference. Visit our website at: http://www.harborfreight.com Email our technical support at: productsupport@harborfreight.com Email our engine support at: predator@harborfreight.com DANGER Do not use in Use at least 20 feet away from...
  • Page 2: Important Safety Instructions

    10. Use only lubricants and fuel recommended in this manual. Page 2 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 3: Operating Precautions

    Generator until the sensor is working and efficiently powered by a portable generator. properly. For technical questions, please call 1-888-866-5797. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 3...
  • Page 4 22. Secure the Generator on transport vehicles to the equipment for operations different from those prevent the tool from rolling, slipping, and tilting. intended could result in a hazardous situation. 23. Industrial applications must follow OSHA requirements. Page 4 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 5 2400 4800 12 AWG 10 AWG 3000 6000 12 AWG 10 AWG 8 AWG 3600 7200 10 AWG 8 AWG 4200 8400 8 AWG 6 AWG 4800 9600 6 AWG ITEM 59205 For technical questions, please call 1-888-866-5797. Page 5...
  • Page 6: Service Precautions

    6. Wipe up any spilled fuel and allow excess to evaporate before starting engine. To prevent FIRE, do not start the engine while the smell of fuel hangs in the air. SAVE THESE INSTRUCTIONS. Page 6 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 7: Specifications

    Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information, refer to the last pages of this manual. Components and Controls Fuel Gauge (L 14-30R) (5-20R) ITEM 59205 For technical questions, please call 1-888-866-5797. Page 7...
  • Page 8 Connect tools and equipment only to the Receptacle (120 volt or 240 volt) that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used. Page 8 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 9 Generator Control Panel to the buried electrode. For additional information on grounding methods, please see the National Electrical Code. NOTICE: There is a permanent conductor between the portable generator stator winding (Neutral Conductor) and the frame. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 9...
  • Page 10 High Altitude Kit parts List - A Not present part Description on some Main Jet 3000-6000 ft. Solenoid Generators Main Jet 6000-8000 ft. Screws Bolt Seal Fuel Cup Seal Solenoid Seal Page 10 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 11 (The SAE Viscosity Grade chart on page 18 in the Service section shows other viscosities to use in different average temperatures.) 6. Thread the dipstick back in clockwise. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 11...
  • Page 12: Using The Generator

    SERVICE section. d. Press Reset button in for use. Reset Button RESET TEST Test Button 120 Volt GFCI Receptacle Page 12 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 13: Starting The Engine

    Note: Moving the Choke Lever too fast could stall the engine. IMpORTANT: Allow the engine to run at no load for five minutes with no load after each start-up so that the engine can stabilize. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 13...
  • Page 14: Connecting Electrical Loads

    1. Make sure that ALL circuit breakers are reset before starting the Generator again. 2. Adjust the plugs so the loads are Evenly distributed shared across outlet circuits. over outlets: To achieve rated output from the Generator, distribute loads over outlets. Page 14 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 15 For most lights or heaters: Central AC - 10,000 BTU 1500 1500 there are no additional start-up watts. Furnace Fan - 1/2 HP 1400 Space Heater 1800 Window AC - 10,000 BTU 1200 ITEM 59205 For technical questions, please call 1-888-866-5797. Page 15...
  • Page 16: Stopping The Engine In An Emergency

    Stopping the Engine Under Normal Conditions 1. Before turning off the Engine, turn off all electrical loads, RESET then unplug them. TEST 2. Turn the Engine Switch off. 3. Close the Fuel Valve. Page 16 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 17: Cleaning, Maintenance, And Lubrication

    4. Clean carbon build-up from combustion chamber – Replace fuel line if necessary Service more frequently when used in dusty areas. These items should be serviced by a qualified technician. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 17...
  • Page 18: Checking And Filling Fuel

    Air Cleaner Cover before use. area away from bystanders, use pressurized air to blow dust out of the air filter. If this does not get the filter clean, replace it. Page 18 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 19: Spark Plug Maintenance

    Fill tank in a well-ventilated area away from ignition sources. If the engine is hot from use, shut the engine off and wait for it to cool before adding fuel. Do not smoke. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 19...
  • Page 20 Engine must be started every 3 months and allowed or if the Engine does not start. to run for 15  –   2 0 minutes or the Warranty is VOID. Page 20 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 21: Troubleshooting

    2. Engine mounted on slope, 2. Operate engine on level surface. triggering low oil shutdown. Check engine oil level. Follow all safety precautions whenever diagnosing or servicing the equipment or engine. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 21...
  • Page 22 3. Intake valve stuck or overheated engine. 3. Have qualified technician diagnose and service engine. 4. Incorrect timing. 4. Check engine timing. Follow all safety precautions whenever diagnosing or servicing the equipment or engine. Page 22 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 23: Please Read The Following Carefully

    Note: If product has no serial number, record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Specify UPC 193175494276 when ordering parts. ITEM 59205 For technical questions, please call 1-888-866-5797. Page 23...
  • Page 24: Parts List

    Plug, Rubber Regulator, Voltage Protector, Oil Cover, Motor Tail Bolt Bolt Arm, Governor Tank, Fuel Washer, Flat Sleeve, Fuel Tank Rubber Bush Spring, Throttle Valve Returning Washer, Flat Rod, Governor Bolt Page 24 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 25 Seat, Engine Frame Shock Absorption Protector, Overcurrent Bolt Rain Cover Receptacle Socket Subassembly, Power Supply Cushion, Engine Frame Right Bridge, Rectification Rain Cover Receptacle Jacket,Rubber Socket Subassembly, Power Supply Cushion, Engine Frame ITEM 59205 For technical questions, please call 1-888-866-5797. Page 25...
  • Page 26: Assembly Diagram

    Assembly Diagram Page 26 For technical questions, please call 1-888-866-5797. ITEM 59205...
  • Page 27: Emissions Control System Warranty

    The nearest Harbor Freight Tools retail store can be found on the internet at http://www.harborfreight.com. ITEM 59205 For technical questions, please call 1-888-866-5797.
  • Page 28 26677 Agoura Road • Calabasas, CA 91302 • 1-888-866-5797...

Table of Contents