a Target receiver selection
Allows you to select the receivers that will perform
scanning for each frequency band. Scanning will not be
performed for frequency bands for which [Do not scan] is
selected.
When the [Reflect recommended GP/CH] checkbox is
selected in the [Channel Plan Adviser] window and you
apply the settings to the [Spectrum Analyzer] tab, the
receivers that will perform scanning will be selected
automatically.
In such cases, if multiple receivers that correspond to a
frequency band exist, the receiver with the earliest IP
address will be selected. However, if a DWR-R02DN is
included, it will be selected regardless of its IP address.
Scanning is performed on CH1 of each receiver.
The operations will vary depending on the model of the
receiver.
DWR-R01D/R02D
To receive the transmitter signal on CH2, configure the
same band setting as that for CH1 scanning. If different
bands are selected for CH1 and CH2, audio interruption
will occur on CH2.
DWR-R02DN
To receive the transmitter signal on CH2, configure the
same band block setting as that for CH1 scanning. If
different band blocks are selected for CH1 and CH2, audio
interruption will occur on CH2.
• Example for North American models:
To prevent audio interruption when the frequency band
setting for CH2 is set to TV14-17, set the frequency band
that will be used for CH1 scanning to a band that belongs
to band block U14(TV14-25) (TV14-17, TV18-21, or
TV22-25).
Band block
U14(TV14-25)
U30(TV30-41)
U42(TV42-51)
• Example for European models:
To prevent audio interruption when the frequency band
setting for CH2 is set to TV21-23, set the frequency band
that will be used for CH1 scanning to a band that belongs
to band block CE21(TV21-29) (TV21-23, TV24-26, or
TV27-29).
Band
TV14-17
TV18-21
TV22-25
TV30-33
TV34-36
TV38-41
TV42-45
TV46-49
TV50-51
Band block
CE21(TV21-29)
CE33(TV33-40)
CE42(TV42-50)
b Scan count setting
Continuous scan: After scanning starts, it is performed
continuously until the [Stop scan] button is clicked.
Specified count scan: After scanning starts, scanning is
performed the number of times specified in [Repeat
count].
c Other settings
Frequency Interval: Select from 125 kHz or 25 kHz as
the interval at which to scan.
[Peak hold]
Select whether to hold and display scanning result values
for each frequency.
ON: The highest RF level of a set of scanning sessions
(during [Continuous scan] or when [Repeat count] is set to
2 or higher for [Specified count scan]) is displayed in the
graph.
OFF: The most recent RF level of a set of scanning
sessions (during [Continuous scan] or when [Repeat
count] is set to 2 or higher for [Specified count scan]) is
displayed in the graph.
d Close button
Closes the [Scan parameter] window.

[Simple Status Viewer] Tab

The [Simple Status Viewer] tab allows you to narrow
down the information registered to each page of the status
viewer to a certain few items, such as the RF meter, QL
meter, and alerts, and display only those items for easier
monitoring.
By reducing the number of items displayed, the display
area for each channel is increased, making the simplified
status viewer ideal for systems with fewer channels to
manage.
42
Band
TV21-23
TV24-26
TV27-29
TV33-35
TV36-37
TV38-40
TV42-44
TV45-47
TV48-50