COMSPHERE 3800 Series Modems – Model 3830
S85
Fast Disconnect
Allows the modem to disconnect immediately after receiving a disconnect
command from a local DTE or its own diagnostic control panel.
Register has the following values:
0 = Disable
1 = Enable
Factory setting is Disable.
S88
Straps When Disconnected
Determines if configuration options in the Active (Saved) configuration
area are loaded to Active (Operating) when the modem disconnects.
Register has the following values:
0 or 231 = No Change
1 or 232 = Reload
Factory setting is No Change.
S89
V.42 ARQ Window Size Increase
Register allows the V.42 Automatic Request for Transmission (ARQ)
window size to be set to a value from 6 to 15 frames to accommodate
satellite delays.
Register has the following values:
0 = 6 frames (default)
1 = 7 frames
2 = 8 frames
3 = 9 frames
9 =15 frames
This command applies only to connections made using V.42 bis data
compression or V.42 error control.
Factory setting is 6 frames.
4-42
Table 4-3
(14 of 15)
Model 3830 S-Registers