Dial TX Level: Permissv(– 9)
Nxt Permissv(– 9) Programmable –10 dBm –11 dBm –12 dBm –13 dBm
–14 dBm –15 dBm –16 dBm –17 dBm –18 dBm –19 dBm
–21 dBm –22 dBm –23 dBm
–28 dBm –29 dBm
Dial Transmit Level. Sets the power output level of the transmit signal over dial lines.
Permissive (– 9 dBm) – The modem transmits data at approximately – 9 dBm. This is
true whether the modem is connected to an RJ11-type permissive jack or to an RJ41 or
RJ45 programmable jack.
Programmable – The modem transmits at a predetermined level set by programming a
resistor in the RJ41 or RJ45 jack. The program resistor value is only read upon
power-up or after reset. This configuration option is valid only for the Model 3811
modem.
ETC 1.0_Cell – Transmit level is automatically adjusted in response to line conditions
according to the proprietary Enhanced Throughput Cellular 1.0 specification. Use only
with remote modems set to ETC 1.0_Cell, and limit the data rate to 4800 bps.
ETC 1.1_Cell – Transmit level is automatically adjusted in response to line conditions
according to the proprietary Enhanced Throughput Cellular 1.1 specification.
The factory default is Permissv(– 9).
AT command for Permissive mode is &J0.
AT command for Programmable mode is &J1.
AT commands for –10 through –32 dBm are &
AT command for ETC 1.0_Cell is &
AT command for ETC 1.1_Cell is &
Changes to AT Commands
AT Command
or S-Register
2
Dial Line Configuration Options
–30 dBm –31 dBm –32 dBm ETC 1.0_Cell ETC 1.1_Cell
Tables 14-1 and 14-2
3800 Series AT Commands and S-Registers
&J n
Dial Transmit Level Type
&J0
Permissive
&J1
Programmable (Model 3811 modem only)
Factory setting is Permissive.
NOTE: &J n overrides the &I n command.
S83
MI/MIC Dialing
Register determines if MI/MIC control leads can
be used to force the modem into the originate
handshake after first dialing a call.
Register has the following values:
0 = Disable
1 = Enable (Model 3811 modem only)
Factory setting is Disable.
September 1996
Table 9-4
–24 dBm –25 dBm –26 dBm –27 dBm
I
10 through &
I
32.
I
99.
I
100.
Description
–20 dBm
Front Panel
Branch
Configure\Edit
\Dial Line
Configure\Edit
\Line Dialer