Single package rooftop gas heat/electric cooling unit with puron (r-410a) refrigerant 7.5 to 15 nominal tons
Table of Contents

Advertisement

Position:
Example:
Unit Heat Type
48 — Gas Heat Packaged Rooftop
Model Series - WeatherMaker
®
FC — Standard Efficiency (EcoBlue™ Technology)
Heat Options
D = Low Heat
E = Medium Heat
F = High Heat
S = Low Heat with Stainless Steel Exchanger
R = Medium Heat with Stainless Steel Exchanger
T = High Heat with Stainless Steel Exchanger
Refrig. Systems Options
M = Two-Stage Cooling/One-Circuit Models
N = Two-Stage Cooling/One-Circuit Models with
Humidi-MiZer
®
System
Cooling Tons
08 = 7.5 tons
09 = 8.5 tons
12 = 10 tons
14 = 12.5 tons
16 = 15 tons
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
2
G = SA Smoke Detector and CO
2
H = RA + SA Smoke Detector and CO
J = Condensate Overflow Switch
K = Condensate Overflow Switch + RA Smoke Detectors
L = Condensate Overflow Switch + RA and SA Smoke Detectors
M = Condensate Overflow Switch + SA Smoke Detector
N = Condensate Overflow Switch + CO
P = Condensate Overflow Switch + RA Smoke Detector and CO
Q = Condensate Overflow Switch + SA Smoke Detector and CO
R = Condensate Overflow Switch + RA and SA Smoke Detector and CO
Indoor Fan Options
2 = Standard/Medium Static Option
3 = High Static Option
5 = Standard/Medium Static Option and Filter Status Switch
6 = High Static Option and Filter Status Switch
Coil Options – RTPF (Outdoor – Indoor – Hail Guard)
A = Al/Cu – Al/Cu
B = Precoat Al/Cu – Al/Cu
C = E-coat Al/Cu – Al/Cu
D = E-coat Al/Cu – E-coat Al/Cu
E = Cu/Cu – Al/Cu
F = Cu/Cu – Cu/Cu
M = Al/Cu – Al/Cu – Louvered Hail Guard
N = Precoat Al/Cu – Al/Cu – Louvered Hail Guard
P = E-coat Al/Cu – Al/Cu – Louvered Hail Guard
Q = E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guard
R = Cu/Cu – Al/Cu – Louvered Hail Guard
S = Cu/Cu – Cu/Cu – Louvered Hail Guard
APPENDIX A — MODEL NUMBER NOMENCLATURE
1
2
3
4
5
6
7
8
4
8
F
C
D
M
0
8
2
2
2
2
Fig. A — Model Number Nomenclature
9 10 11 12 13 14 15 16 17 18
A
2
A
5
-
8
A
0
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Access Panels
4 = Hinged Access Panels and
5 = Hinged Access Panels and
6 = 4" MERV 13 High Efficiency Filter Track
7 = Unpowered Convenience Outlet and 4" MERV 13
8 = Powered Convenience Outlet and 4" MERV 13
9 = Hinged Access Panels and 4" MERV 13 High
A = Hinged Access Panels, Unpowered Convenience
B = Hinged Access Panels, Powered Convenience
2
Intake / Exhaust Options
A = None
B = Temperature Economizer with Barometric Relief
F = Enthalpy Economizer with Barometric Relief
U = Temperature Ultra Low Leak Economizer
with Barometric Relief
W = Enthalpy Ultra Low Leak Economizer
with Barometric Relief
Base Unit Controls
3 = SystemVu™ Controller
8 = Electromechanical Controls — can be used with POL224
EconomizerONE (With Fault Detection and Diagnostic)
Design Revision
- = Factory Design Revision
Voltage
1 = 575-3-60
5 = 208/230-3-60
6 = 460-3-60
72
A
0
Packaging Compliance
0 = Standard
1 = LTL
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
N = Phase Monitor/Protection
Q = Phase Monitor/Protection
and Non-Fused Disconnect
R = Phase Monitor/Protection
and Thru-The-Base Connections
T = Phase Monitor/Protection with Non-Fused
Disconnect and Thru-The-Base Connections
1 = High SCCR (Short Circuit Current Rating)
Protection
2 = High SCCR Protection and Thru-The-Base
Connections
Unpowered Convenience Outlet
Powered Convenience Outlet
High Efficiency Filter Track
High Efficiency Filter Track
Efficiency Filter Track
Outlet and 4" MERV 13 High Efficiency Filter Track
Outlet and 4" MERV 13 High Efficiency Filter Track

Advertisement