a) Connect the 2 connecting cables (1 and 2).
Wire gauge: UL1015 AWG8
Connector model: Plastic part: 992-BK, Connector part: 5952-BK
b) Connect the 2 sensing cables (4 and 5).
Wire gauge: UL2517 AWG22/2C
Connector model: Plastic part: SMP-02V-NC, Connector part: SHF-001T-0.8BS
c) Connect the power cable and sensing cable to the power supply.
24. Connect the communication cable.
a) Pull out the filter slightly to create a gap for the communication cable (3).
b) Feed the communication cable through the gap and locate the wire in the opening.
c) Connect the communication 4-pin plug into the socket on the side of the display in the ADB. Ensure that the
cable is located into the small opening away from the filter area.
d) Secure excess cable into the holders.
Installing the ADB
25. Stack the duct sections and place against the roof thickness: Ensure that the duct height matches the roof height
or use the table as guide.