4.2 Active Line Modules with internal air cooling

4.2
Active Line Modules with internal air cooling
4.2.1

Description

Active Line Modules generate a constant, regulated DC voltage in the DC link from the 3-
phase line supply voltage that supplies the connected Motor Modules with power.
This ensures that they are not influenced by line voltage fluctuations.
When the motors are in feedback mode, Active Line Modules supply power back to the line
supply. The regenerative feedback capability of the modules can be deactivated by
parameterization.
The DC link starts precharging as soon as the line voltage is applied and is independent of
its phase sequence direction. Load can be applied to the DC link after the module has been
enabled. An optional main contactor is required for disconnecting the voltage.
Active Line Modules can be directly connected to TN, IT and TT systems. The Line Modules
have an integrated overvoltage protection function.
WARNING
Danger to life if the fundamental safety instructions and remaining risks are not carefully
observed
If the fundamental safety instructions and remaining risks in Chapter 1 (Page 25) are not
observed, accidents involving severe injuries or death may occur.
• Adhere to the fundamental safety instructions.
• When assessing the risk, take into account residual risks.