Error
Description
code
5097
Flash
management
full
5096
Storing
unsuccessful
5095
Restoring
unsuccessful
6099
6098
7698
Light pipe
temp high
7697
Light pipe
temp open
7696
Light pipe
temp short
7695
Red front
DMD temp low
7694
Red front
DMD temp
high
7693
Red front
DMD temp
open
7692
Red front
DMD temp
short
7691
Green front
DMD temp low
7690
Green front
DMD temp
high
7689
Green front
DMD temp
open
7888
Green front
DMD temp
short
7687
Blue front
DMD temp low
7686
Blue front
DMD temp
high
7685
Blue front
DMD temp
open
R59770017 FLM HD14 26/09/2006
Error
Warn-
Caused by
ing
-
Yes
Internal Backup device has
reached its maximum capacity
-
Yes
Storing the custom settings into
internal backup device has failed
-
Yes
Restoring the custom settings from
internal backup device has failed
Yes
Yes
High temperature on light pipe
entry
Yes
Yes
Temperature sensor on light pipe
not connected
Yes
Yes
Temperature sensor on light pipe
shorted
No
Yes
Low temperature on red DMD
Yes
Yes
High temperature on red DMD
Yes
Yes
Temperature sensor on Red DMD
not connected
Yes
Yes
Temperature sensor on Red DMD
shorted
No
Yes
Low temperature on green DMD
Yes
Yes
High temperature on green DMD
Yes
Yes
Temperature sensor on green
DMD not connected
Yes
Yes
Temperature sensor on green
DMD shorted
-
Yes
Low temperature on blue DMD
Yes
Yes
High temperature on blue DMD
Yes
Yes
Temperature sensor on blue DMD
not connected
C. Troubleshooting
Action
Call a qualified service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Switching on the lamp will heat up
the DMD
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Switching on the lamp will heat up
the DMD
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer
Call a qualified service engineer
Switching on the lamp will heat up
the DMD
Check if air slots are free.
Clean air filters.
If problem persists, call a qualified
service engineer
Call a qualified service engineer