LIGHTING
WITHOUT SAFETY VALVE DEVICE
To
ignite
the
instructions are to be followed:
1.
Press in the corresponding knob and
turn counter-clockwise (fig. 2.2) to the
full flame position marked by the "
symbol (fig. 2.3); hold the knob in until
the flame has been lit.
In the case of a mains failure light the
burner with a match or lighted taper.
2.
Adjust the gas valve to the desired
position.
To turn it off, turn the knob towards the
right, up to the safety click.
Note: If your local gas supply makes it
difficult to light the burner with the knob set
to maximum, set the knob to minimum and
repeat the operation.
VERY IMPORTANT NOTE FOR THE MODELS WITHOUT SAFETY VALVE DEVICE
•
WARNING
•
TAKE SPECIAL CARE
The appliance must be supervised during the use of the gas burners.
If the burner flames should go out for some reason, the gas valve will continue to
produce a flow of unburned gas through the burner. In that case, as soon as the
flames should go out, turn the burner control knob to the "
at least 1 minute and then repeat the lighting procedure.
If a burner does not remain lit in the minimum position, check the chapter
"ADJUSTMENT OF THE MINIMUM OF THE TOP BURNERS" in the "ADVICE FOR
THE INSTALLER" section.
If a burner does not remain lit in all the settings, check that the burner parts and the
injector are dry and clean and that they are correctly in place.
GAS
BURNERS
burner,
the
following
NOTE: The knob and symbols may vary.
"
Fig. 2.3
" (off) position, wait for
27
27