Some models - for the gas category check the data label attached on the appliance
Cat: I 3+
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Fish (F)
Triple-ring (TR)
Dual (DB) - inner crown
Dual (DB) - outer crown
(*)
Power calculated with inner crown operating.
(**) Power calculated with inner and outer crowns operating.
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Fish (F)
Triple-ring (TR)
Dual (DB) - inner crown only
Dual (DB) - outer crown
Dual (DB) - inner & outer crown
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
GAS MAINTENANCE
TABLE FOR THE CHOICE OF THE INJECTORS
Nominal
Power [kW]
3,40 (**)
Reduced
Power [kW]
1,00
0,40
1,75
0,45
3,00
0,75
2,65
1,50
3,50
1,50
0,80 (*)
0,40 (*)
1,50 (**)
Air necessary for combustion [m
G30/G31
28-30/37 mbar
Ø injector
[1/100 mm]
50
66
87
81
93
46
65 (x2)
/h x kW)
3
/h]
3
2,00
3,50
6,00
5,30
7,00
1,60
6,80
8,40
15
15