Gun Washer Shutdown and Care
WARNING
PRESSURIZED EQUIPMENT HAZARD
To reduce the risk of an injury from accidental
spray, splashing fluid, or moving parts, follow the
Pressure Relief Procedure, covered in steps 1
and 2 below, when you shut down the gun washer
and before you check, clean, or service any of the
system equipment.
1. Disconnect the air supply.
2. Drain the solvent from the gun washer tank daily,
when you shut down the system. Place a proper
solvent container under the fluid drain valve on the
bottom of the tank and open the fluid drain valve.
WARNING
FIRE AND EXPLOSION HAZARD
The PRO-Wash gun washer is classified
as a temporary storage container. To re-
duce the risk of fire or explosion, be sure
to drain the solvent into a proper storage
container and store it according to the
local code for flammable liquids when
shutting down your system.
3. Wipe the inside of the tank with a cloth or use a
brush to remove any built-up paint residue.
4. Thoroughly clean the gun washer filter (item 12 in
the Parts Drawings) with a brush.
5. Change the solvent completely when it is no longer
thoroughly cleaning the painting equipment. If the
gun washer is being filled with old solvent, be sure
to filter the solvent before filling the gun washer
tank.
NOTE: If the solvent is thoroughly filtered daily to
remove paint residue, it can usually be reused for 2 to
8 weeks (depending on gun washer usage).
WARNING
FIRE AND EXPLOSION HAZARD
To reduce the risk of fire or explosion,
always clean-up any solvent leaks or
spills immediately. Repair any leaking
components before operating the gun
washer again.

Shutdown and Care

Air Cut-off Switch and Reset Block
WARNING
EQUIPMENT MISUSE HAZARD
A safety device has been installed to shut off the
pump when the gun washer lid is opened. Do not
tamper with or alter this device. Serious injury, in-
cluding blindness, could result.
The air connections between the air cut-off switch and
reset block are color coded. They must always be con-
nected as shown in Fig. 5.
Air Cut-off Switch and Reset Block
Air Supply
Black Color
Limit
Switch
Lid Closed Signal
Blue Color
Start
Switch
Fig. 5
Pump
Couple
r
Air Filter/
Regulator
Main
Air
03306
308393