E-5
Input Switch
Input
& 100A Breaker
Rectifier
+
-
-
Aux.
Trans
Fan
Relay
Fan
Fan
Motor
Motor
230VAC
230VAC
6
Pin
Amphenol
OUTPUT RECTIFIER AND CHOKE
The output rectifier receives the AC output from the
main transformer secondary windings and rectifies it
to a DC voltage level. Since the output choke is in
series with the positive leg of the output rectifier and
also in series with the welding load, a filtered DC out-
put current is applied through the machine's output
terminals.
THEORY OF OPERATION
FIGURE E.5 – OUTPUT RECTIFIER AND CHOKE
Main Switch Board
Reconnect
Switch
IGBT Drive Signal
Precharge Relay Control
To
Shut Down Signal
Fan
Motors
18 VAC
Relay Control
V275-S
#1 Primary
Current
Feedback
Choke
To Control
Board
Shunt
#2 Primary
Current
Feedback
Output
Diodes
#1 Primary
Current
Feedback
Control Board
Hot
Arc
Output
Mode
Start
Control
Force
E-5
Positive
+
Output
Terminal
Negative
-
Output
Terminal
Thermostats
Thermo.
LED
Local
Remote

Advertisement