Component Testing
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Evaporator heater
Activated when defrost thermostat,
(defrost)
defrost timer, and freezer control
complete circuit through heater.
Thermostat
Thermostat is in a series circuit with
(defrost)
terminal 2 of defrost timer, and defrost
heater. Circuit is complete if evaporator
fan motor operates when cold.
Controls the circuit from freezer
thermostat through defrost terminator to
defrost heater. Opens and breaks circuit
when thermostat senses preset high
temperature.
8
!
WARNING
Check resistance across heater.
To check defrost system :
1. Thermocouple defrost thermostat and plug refrigerator into wattmeter.
2. Turn into defrost mode. Wattmeter should read specified watts (according to
Technical Data Sheet).
3. When defrost thermostat reaches specified temperature ±5°F (see Technical
Data Sheet), thermostat should interrupt power to heater.
Test continuity across terminals.
With power off and evaporator coil below freezing, thermostat should show
continuity when checked with ohmmeter. See "Heater, evaporator (defrost)"
section for additional tests.
After defrost thermostat opens, thermostat remains open until end of defrost cycle
and refrigerator starts cooling again. Defrost thermostat senses a preset low
temperature and resets (closes).