Filling The Cooling Circuit - Fronius CU 1800 Operation & Maintenance Manual

Water chiller
Table of Contents

Advertisement

Available languages

Available languages

Filling the coo-
When using the water chiller for the first time, the entire cooling circuit must be filled with
ling circuit
cooling liquid.
Proceed as follows:
1.
Press the buttons RUN / STOP and MENU simultaneously: PUMP function.
► The pump is put into operation.
► The RUN indicator LED flashes green.
2.
Due to the pumping process, the filling level in the cooling liquid tank can drop to
the lower limit.
► An acoustic warning signal sounds.
► Alarm AL01 (low level) is shown on PV display.
► The ALARM indicator LED flashes red.
► The fluid level indicator lights up.
► The pump is stopped.
3.
Press both ARROW buttons simultaneously: RESET function.
► The acoustic alarm signal is switched off.
108