CONTENTS Please Note......................1 Parts Identification....................1 Control Panel......................2 To Operate......................3 To Empty the Bucket When WATER FULL.............3 To Drain Water....................... 4 To Clean and Install the Filter.................4 Compressor Self-protection................... 5 Defrosting Control....................5 Installation......................5 To Move......................... 6 To Clean the Unit....................
Please Note 1. The unit runs with 220V-240V AC / 50Hz power. 2. Please use a qualified receptacle,and be aware not to share with other electric appliances. 3. Before cleaning, maintenance or, non-operated for a long period, please turn power off and unplug the power cord.
Control Panel WATER FULL POWER COZY CONTINOUS RUN Indicator ON/OFF Button indicator Indicator Indicator WATER FULL Indicator Indicator Indicator Button ON/OFF DEHUMIDIFY Indicator POWER WET COZY CON T. WATER FULL WATER FULL MODE. MODE Selection Button Mechanic Models Electronic Models 1/0 Button: By pressing this button, you can turn on or turn off the unit.
To Operate 1. Plug the cord to the proper power requirement. The computer system of the unit will have a self-check. If it is normal, the POWER indicator starts flashing. Press 1/0 button, and the POWER indicator Will light. 2. Make sure to fit the bucket in right position. (When the bucket is full or is not in place, the "WATER FULL"...
To Drain Water You may use a hose with an inner diameter of 11.5 mm for continuous drainage: 1. Use a screw driver or so to remove the pick-up at the back (don't use hand, or may cause injury), then push the hose to a connector inside the hole.
Compressor self-protection The compressor will restart at least 3 minutes later after it stops for self-protection. If you turn on the unit immediately, the equipment will start operating only 3 minutes later. Defrosting control Auto Defrosting Operation, Controlled by Microcomputer, starts when the evaporator generates frost. This special function ensures the unit running when the temperature is down to 5 C.
To Move 1. Unplug the cord and empty the water bucket before moving the unit. 2. Bottom casters are provided to allow you to move the unit easily . For moving upstairs or downstairs, lift it by two persons by holding at the bottom and settle it carefully. 3.
Troubleshooting Problem Cause Solution 1. Power off Power on Restore power cord 2. Power cord unplugged 3. Bucket displaced or water is full Pour away water and position bucket Fail to Run 4. Defrosting After defrosting, the unit will dehumidifying again. 1.