Operation State - East Tester ET5406A+ User Manual

Single channel programmable dc electronic load
Table of Contents

Advertisement

ET5406A+/ET5407A+ Programmable DC Electronic Load - User Manual
Fig. 4-2-5 A and B Pulse Width Time

4.3. Operation State

After users press the [ON] button to activate the channel, it will exhibit different operation
behaviors based on the specified settings.
Continuous Mode (Cont): In this mode, after the test is initiated, the load can continuously
switch between values A and B.
Fig. 4-3-1 Continuous Mode
Pulse Mode (PULS): In this mode, after the test is initiated, the load switches from value A to
value B upon receiving each trigger signal. After maintaining value B for the pulse width time, it
reverts back to value A.
Fig. 4-3-2 Pulse Mode
Trigger Mode (trIG): In this mode, after the test is initiated, the load switches between values A
and B upon receiving each trigger signal. In this mode, pulse width settings will not take effect.
Fig. 4-3-3 Trigger Mode
5. LIST Test Operations
The LIST test feature streamlines the testing of the device under test across various load
conditions, promoting automation in production line testing. By pre-configuring the steps of the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Et5407a+

Table of Contents