Dometic 10 Series Installation Manual page 25

Absorber refrigerator
Hide thumbs Also See for 10 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
RMD10.5(X)(T)(S)
No. in
fig. i, page 11
13
14
15
16
17
18
19
20
21
22
23
24
25
DC power
!
WARNING! Fire hazard!
• The supply line to the heating element must be protected with a
20 A fuse.
• The supply line to the electronics must be protected with a 2 A fuse.
A
NOTICE!
The respective positive and negative supply lines of the DC connections
for electronics (fig. i 23, page 11) and heating element (fig. i 24,
page 11) may not be joined with one another and carried on a single
wire. This can cause electrical interference or damage to electrical com-
ponents.
Please note the following cable sizes:
• Cross section for connections to the heating element: min. 6 mm²
To guarantee a proper cooling performance ensure that the voltage loss is
<0.8 Vg from the power supply to the refrigerator connection terminal.
EN
Description
Display
Heating frame
Fan 2 (if options module is available)
Fan 1 (if options module is available)
Options module
DC supply oven (if options module is available)
DC supply options module
CI-Bus connection
DC power supply
12 V terminal housing (front view)
AMP/TE Tyco: 180906
CS Colombo: 63N025
DC supply cable electronics
DC supply cable heating element
Internal DC supply, max. 1 A (options module, oven, fan)
Connecting the refrigerator
25

Advertisement

Table of Contents
loading

Table of Contents