RMD10.5(X)(T)(S)
I
NOTE
Optionally, you can use the Dometic flexible gas connection pipe to
keep the installation tensionless.
It must be possible to shut off the refrigerator from the gas line separately by means
of a shut-off device. The shut-off device must be easily accessible.
➤ Connect the refrigerator securely by hand to the gas supply (fig. h, page 10):
A
NOTICE!
Always use a backup wrench (size 17 mm) when connecting the gas
supply line to the refrigerator's gas inlet fitting.
No. in
fig. h, page 10
1
2
3
4
➤ Have a leak test and a flame test performed by an authorized specialist after pro-
fessional installation.
Ensure you are issued with a certificate of inspection and hand this certificate to
the end user for safekeeping.
EN
Description
Screw M4 (Torx TX20),
Tightening torque: 2 Nm
Refrigerator gas connection:
M14 x 1.5 (d = 8 mm/ISO8434 (DIN2353))
Gas pipe with ring coupling (size 17),
Tightening torque: 25 Nm
Backup wrench (17 mm)
Connecting the refrigerator