7
464 and 466 Opt ion 1 0
O P T IO N
1 0
Opt ion 1 0 will operat e wit h any ot her opt ion except
Opt ion 5 .
C
INTRODUCTION
SPECIFICATION
1
AC Requi rem ent s
Opt ion 1 0 for t he 464 and 466 St orage Oscilloscopes
provides m ore- versat ile vert ical m ode cont rols and
full
t im e t rigger view . Full -t im e t rigger view perm it s t he user t o
com pare t he t rigger signal wit h t he Channel 1, Channel 2 ,
or Add signal .
Sam e as non - Opt ion 1 0 oscilloscopes.
Tem perat ure
C
The sam e operat ing and non - operat ing ranges as osci llo
scopes wit hout Opt ion 1 0 .
The Opt ion 1 0 vert ical m ode cont rols perm it t he display
of any com binat ion of Channel 1 , Channel 2 , and Trigger
Vi ew in eit her Chopped or Alt ernat e m ode .
a
Elect ri cal Charact eri st i cs
Sam e as non - Opt ion 1 0 oscilloscope except as follows :
Charact erist ic
Perform ance Requirem ent
Pressing t he TRIG VIEW but t on causes t he signal con
nect ed t o t he A TRIGGER ext ernal connect or t o be dis
played when t he A TRIGGER SOURCE cont rol is in t he
EXT or EXT : 1 0 posit ion . The t rigger -view display is
posit ioned wit h t he A TRIGGER LEVEL cont rol .
Deflect ion Fact or of
Trigger Vi ew Signal ( t he
A Trigger )
Figure Opt ion 1 0-1 shows Vert ical Mode and Bandwidt h
Lim it cont rols .
EXT
EXT = 1 0
1 00 m V / div + 5%
1 V/ div + 5 %
Cent ering of Triggering
Point
Wit hin 1 .0 division of
cent er screen ,
CH 1
SAFETY CONSIDERATIONS
Opt ion 1 0 becom es an int egral part of t he 464 and 466
oscilloscopes . The safet y considerat ions for t he non - Opt ion
1 0 oscilloscopes apply .
A
EXT
ONLY
TRIG
VIEW
FUNCTION OF CONTROLS
20 MHZ
ADD
VERT MODE Cont rols
C
VERT
MODE
BW
LIMIT
CH 1- When pressed in , displays Channel 1 . signal . To
end t he signal display , release t he CH 1 but t on by pressing
it .
C
ALT
OUT
CHOP
TRIG VIEW - When t he TRIG VIEW but t on is pressed
in and t he A TRIGGER SOURCE cont rol is in EXT or EXT
1 0 posit ion , t he signal applied t o t he ext ernal t rigger con
nect or is displayed . To end t he display of t he signal at t he
ext ernal t rigger connect or, release t he TRIG VIEW but t on
by pressing it .
CH2
1 753-1 01
ADD - When pressed in , displays t he algebraic sum of
t he Channel 1 and Channel 2 input signals . To end t he
ADD m ode display , release t he ADD but t on by pressing it .
C
7
Figure Opt ion 1 0-1. Vert ical Mode and Bandwidt h Lim it cont rols
for 464/ 466 .