UNI-T UT219PV User Manual page 25

Table of Contents

Advertisement

UT219PV User Manual
9.999kΩ
99.99kΩ
* Precision range: 1~100% of range
*For continuity test at 999.9Ω, fast response cannot be achieved. For resistance ≤30Ω, continuous
sound is generated and green backlight is lit up. For resistance ≥50Ω, no sound is made.
8. Diode
Range
2.800V
* Open-circuit voltage: About 3 V
* Residual reading under short-circuit condition: ≤3 digits
9. Capacitance
Range
100.0μF
1000μF
* Residual reading under open-circuit condition: ≤5 digits
* Measured value = Displayed value - Residual reading
* Precision range: 5~100% of range
10. Temperature
Range
-40℃~400℃
-40℉~752℉
* Equipped with Type K (NiCr~NiSi) thermocouple
* Open-circuit indication: OL
* Short-circuit indication: Ambient temperature
* If each ambient temperature difference of the Clamp Meter reaches ±5℃, the accuracy can be
adopted after 1 hour.
11. Table of Auto Hold Function
0.001kΩ
0.01kΩ
Resolution
0.001V
Resolution
0.1μF
1μF
Resolution
0.1℃
0.2℉
Table of Auto HOLD Function
Function
Threshold
ACV
10V
DCV
10V
Ω
99.99KΩ
Overload protection
1500V AC/DC
Accuracy
±(1.0%+5)
Accuracy
±(1.0%+30)
±(1.0%+60)
Fluctuation range/Increment
2V
2V
2.0Ω/20Ω/0.2KΩ
Overload protection
1500V AC/DC
Overload protection
1500V AC/DC
25 / 27