Notes on the recovery cylinders
• The drained refrigerant must be filled into refrigerant recovery cylinders.
• The recovery cylinders must be equipped with pressure relief valve and an associated shut-off valve.
• The recovery cylinders must be evacuated and cooled before draining.
• The connected hoses must be equipped with leak-free disconnect couplings and be in good condition.
• The recovered refrigerant shall be processed according to local legislation in the correct recovery cylinder,
and the relevant waste transfer note arranged.
• Do not mix refrigerants in recovery units and especially not in cylinders.
Deinstalling the roof air conditioner
1.
Disconnect the vehicle battery.
2. Ensure that the roof air conditioner inlets and outlets are not blocked.
3. Remove the ADB from the center cover.
4. Remove the filters.
Dometic FJX EN