Fault
The laundry is too
damp.
Loud noises during
the spin cycle.
Banging noises, rat-
tling in the drain
pump.
Slurping, rhythmical
suction noise.
Fan noise during the
washing phase.
Longer, whirring noise
before the start of the
wash cycle or fabric
softening.
Cause and troubleshooting
Load too small.
Water tap is closed during the drying phase.
Make sure that the water tap also remains open
during the drying phase.
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is below 30
°C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
The water pressure is low.
No remedial action possible.
Laundry is not spun sufficiently.
Always select the highest possible spin speed for
the washing programme in question.
Thick and multi-layered fabrics require a longer drying
time.
Set a timed programme for the subsequent drying.
→ "Programmes", Page 27
Appliance is not correctly aligned.
→ "Aligning the appliance", Page 15
The appliance feet are not fixed.
Secure the appliance feet.
→ "Aligning the appliance", Page 15
Transit bolts have not been removed.
→ "Removing the transit bolts", Page 13.
Foreign bodies have got into the drain pump.
→ "Cleaning the drain pump", Page 43
The drain pump is active, the detergent solution is
pumped out.
Not a fault – normal operating noise.
Process fan is active.
Not a fault – normal operating noise.
Intelligent dosing system dispenses detergent or care
products.
Not a fault – normal operating noise.