Woods SB54.30 Operator's Manual page 29

Table of Contents

Advertisement

Optional Hydraulic Chute Deflector
Figures 29 - 36
■ Keep hands and body away from pressurized
lines. Use paper or cardboard, not hands or
other body parts to check for leaks. Wear safe-
ty goggles. Hydraulic fluid under pressure can
easily penetrate skin and will cause serious in-
jury or death.
1. Figure 29: Remove the adjustment arm (1) by re-
moving the knob (2), the 5/16" x 1" carriage bolt (3)
and the nylon washer (4) at the chute base. Remove
the circle cotter (5), the adjustment arm (1) and the
two 1/2" flat washers (6).
Figure 29. Remove Adjustment Arm
2. Figure 30: Attach the cylinder base (1a) to the chute
base (2) with the pin (3) provided with the cylinder
and the cotter pin (4). Attach the cylinder rod end
(1b) to the deflector (item 5) with the pin (item 3)
provided with the cylinder and the cotter pin (item
4).
Figure 30. Attach Hydraulic Cylinder
MAN1367
( 10/16/2023 )
MAN1367_2023-10.indd 29
MAN1367_2023-10.indd 29
WARNING
3. Figure 31: Using thread sealant, install a 90° 3/8"
NPT male x 1/4" NPT swivel female elbow (1a) on
the port of the cylinder rod side, pointing upwards
and parallel to the cylinder (2). Install a 90° 3/8" NPT
male x 1/4" NPT swivel female (1b) on the port of
the cylinder base at an angle of 10° to the cylinder
(2).
Figure 31. Orient Fittings
4. Figure 32: Using thread sealant, install a 1/4" NPT
female x 1/2" NPT male reducer (2), a male quick
coupler (3) and a dust cap (4) on the end of the two
hoses (1).
Figure 32. Assemble Quick Couplers
5. Figure 33: Connect the two hoses (1) to the 90° 3/8"
NPT male x 1/4" NPT swivel female elbows (2) of
the cylinder. Secure the hoses (1) with a nylon tie
(3) as shown in the figure.
Figure 33. Connect Hoses
Assembly 29