Stove Installation And Connection; Expansion Tank - Teba therm T-17 Installation Manual

Central heating stove with solid fuel
Table of Contents

Advertisement

Flammable materials and furniture should not be placed at a distance of 80 cm in
the radiation area (C) of the flame monitoring cover.
This distance can be reduced to 40 cm when the protection panel is placed between
the stove and the materials that are likely to burn.
Minimum distances for flammable materials and furniture are indicated on the
product label and must not be exceeded. If the floor where the stove needs to be
installed is flammable or heat-sensitive, you should place the product on the ground
protection plate (eg marble or glass base).
In this case the minimum dimensions of stove bottom plate (look at drawing)
should be:
D
50cm (front length)
E
30cm (lateral length from the inner edge of the fire chamber cover)
You can order the floor protection plate from seller when you require.

4.2 STOVE INSTALLATION AND CONNECTION

Product installation and assembly should be done according to the user manual and
by an authorized person. Since our central heating stove with solid fuel for a flat is
designed for interior and provide heat to the ambient, it should not be installed in
bathroom, balcony, cellar, woodshed, etc... The distance between stove and chimney
must be close.
Select an appropriate place for the product. The expansion tank, circulation
pump, mechanical thermostat, indicator panel and chimney connection must
be installed as shown in the installation diagram.

4.2.1 Expansion Tank

After the connection of the expansion tank to the suitable place (wall), it must be
securely connected to the 1"pipe(PVC-metal) and must be connected to 1" records
on the stove, to hot - cold return output and to ¾ connection records on the
expansion tank (see assembly diagram)
The expansion tank vapor output (water discharge) is used to expel the water
vapor caused by pressure from the stove. The water vapor expels by taking a line
from vapor output (water discharge) to the wet floor.