OPERATIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE
INJECTORS OF THE OVEN AND GRILL BURNERS
Some models are provided with a set of injectors for the various types of gas.
If the injectors are not supplied they can be obtained from the "Service Centre".
Select the injectors to be replaced according to the "Table for the choice of the injectors"
(for the gas category check the data label attached on the appliance).
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of
each injector.
OVEN BURNER (Left and right ovens)
Lift and remove the lower panel inside the oven.
Unscrew and remove the burner securing screw "A" (fig. 10.8).
Withdraw the burner as shown in figure 10.8 and rest it inside the oven. Take care not
to damage the safety valve probe and the electric ignition electrode.
Using a 7 mm box spanner, unscrew the injector (indicated by the arrow in fig. 10.9)
and replace it with a new one selected in accordance with the "Table for the choice of
the injectors".
Regulate the air supply to the oven burner as indicated in the section "REGULATION
OF AIR SUPPLY TO OVEN AND GRILL BURNERS"; then replace the burner repeating
the above steps in reverse order.

IMPORTANT: Check the correct operation of the safety valve and the electric
ignition.
A
Fig. 10.8
Fig. 10.9
41