To Adjust The Display Settings - Carrier 33WIFISTAT43FX Installation Instructions Manual

Wi-fi thermostat
Table of Contents

Advertisement

To Adjust the Display Settings

See Table 5 for a list of display settings and specifications.
SETTING
SOUND EFFECT—Select the sound feedback when you press a button.
BACKLIGHT—There are two backlight settings, one for interacting with the thermostat and another for the dormant
screen.
BACKLIGHT ACTIVE—Set the active backlight to 10% to 100% of the full backlight capability.
BACKLIGHT SLEEP—Set the inactive backlight for the dormant screen to 0% to 25% of the full backlight capability.
LOCKOUT ENABLE—Enable or disable adjustments to prevent unauthorized changes from the touchscreen interface.
When LOCKOUT is changed from NO to YES, the user must enter a 3-digit PIN. After setting the LOCKOUT to YES
and entering a PIN, the thermostat locks when the user returns to the home or the dormant screen.
When LOCKOUT is enabled:
The user must enter the 3-digit PIN after pressing any button on the home screen.
If the PIN is entered successfully, the thermostat is unlocked until the dormant screen displays.
After 5 failed attempts to unlock the thermostat, a notification (fault) is sent through the Wi-Fi to the registered owner
of the thermostat. Additional unlock attempts are not allowed for 15 minutes.
NOTE: If the user enables LOCKOUT but does not save a PIN, LOCKOUT automatically disables (sets back to NO).
SET LOCK PIN—The end user can choose or modify their own 3-digit lock PIN for the thermostat. One digit of the 3-
digit PIN flashes to indicate which digit is changeable using the up and down arrows. To change which digit is
adjustable, touch the digit on the display.
NOTE: If LOCKOUT ENABLE is set to NO, the SET LOCK PIN screen does not appear.
CLEAN SCREEN—Completely disables touch functionality for 10 seconds so the screen can be cleaned with a dry nonabrasive cloth. During this
time, a 10-second countdown value shows and then normal touchscreen function resumes.
Two screens display the thermostat software versions. They are for informational purposes only.
APP VERSION displays the application.
BOOT VERSION displays the bootloader.
HUMIDIFY SETPOINT—Sets the humidify setpoint. When the heating equipment is energized and the humidity level is
more than 2% below the humidify setpoint, the humidifier turns on. When the heating equipment turns off or the humidity
level is more than 2% above the humidify setpoint, the humidifier turns off.
NOTES:
If the installer set HUMIDIFIER to NO, this setting is not available.
If the installer did not set the HUM OUTPUT to 1 of the 3 configurable outputs, this setting is not available.
DEHUMIDIFY SETPOINT—Sets the dehumidify setpoint. When the humidity level is greater than the dehumidify
setpoint, dehumidification operates according to the installer configuration for the dehumidifier.
NOTE: If cooling equipment is not available (based on the OUTDOOR EQUIPMENT TYPE selection, then
dehumidification is not available in the thermostat.
HOLIDAYS—View or edit all holidays for the current year. When the current date in the thermostat is the same as a day in the holiday list, the
setpoints for the first UNOCCUPIED time range are used for the entire day unless you later change them. When the HOLIDAYS screen displays,
press SELECT to view the holidays. The up and down arrows scroll through the holidays, displaying one per screen. Maximum number of holidays in
the holiday list is 24.
There are two different holiday formats.
Standard holidays are the same every year, such as Jan 1st and Dec 25th.
Special holidays are occurrences of a day of the week such as Memorial Day, Labor Day, and Thanksgiving. The day of the week is shown in the
heat setpoint location.
For both types of holidays, the duration of the holiday is shown in the cool setpoint location.
The top banner scrolls the holiday details.
To program holidays:
Press SELECT to display the SAVE and CANCEL buttons
When the month flashes, use the up and down arrows to change it.
To change the day of the month, touch the screen location that shows the day of the month and it flashes.
To change the duration, touch the duration value and it flashes.
To delete a holiday, set the duration field to zero and press SAVE. The banner scrolls DELETE HOLIDAY.
To add a holiday, scroll through the list of holidays to the end. The last entry is the ADD HOLIDAY screen. Press SELECT to add a new holiday.
The new holiday is initialized to 1/01 with a duration of one day.
The day of the month advances from 1 to the last day of the month and then Su, Mo, Tu, We, Th, Fr and Sa, and then back to 1. When the days
of the week are displayed, an occurrence value is shown in the heat setpoint. This allows the user to enter a special holiday.
NOTE: If the thermostat has been configured for non-programmable operation, the HOLIDAY screen is not available in the Menu settings.
SCREEN TIMEOUT—Set the number of seconds you want the home screen to stay active without any user interactions
before transitioning to the dormant screen.
Banner displays SCREEN TIMEOUT.
WI-FI ENABLE—Enable (yes) or disable (no) the Wi-Fi functionality for the thermostat. If disabled, the Wi-Fi radio in this
product is turned off and Wi-Fi functionality is unavailable, including SYNC TIME TO SERVER, OUTDOOR
TEMPERATURE via Wi-Fi geolocation, SERVER & WI-FI ERRORS and REMOTE ACCESS SERVICES via APP or
WEB.
FLTR HRS LEFT xxxx—The number of hours left before the filter reminder displays
RESET FILTER—Reset the filter hours to the installer-specified number if the filter is changed prior to the timer counting
down to zero. Press SELECT, use up and down arrows to display YES, and press SAVE.
NOTE: Decrements to the timer happen each hour of total equipment runtime. The accumulated run time hours are
stored to non-volatile memory, but the minutes are not, so a power cycle does not retain partial hour runtime.
FILTER REMINDER displays on the home screen and dormant screen banners when the filter timer counts down to
zero. If you touch the home screen banner when the FILTER REMINDER message displays, the thermostat transitions
directly to FLT HRS LEFT screen. The banner message button is a shortcut to the FLT HRS LEFT screen when the
filter timer has expired. You can access the FLT HRS LEFT screen at any time through the menu.
Table 5 — Display Settings
12
DEFAULT/RANGE
D:
CLCK (Click)
R:
Off, CLCK (Click),
Beep
D:
R:
D:
75%
R:
10 to 100%
(5% Increments)
D:
25%
R:
Missing to 25%
(5% Increments)
D:
No
R:
Yes/No
D:
N/A - no default
R:
000 - 999
D:
15%rh
R:
15 to 5%rh
D:
65%rh
R:
35 to 35%rh
D:
15 seconds
R:
5 to 30 seconds
(5 Second
Increments)
D:
Yes
R:
Yes/No
D:
No
R:
Yes/No