3. UP and DOWN buttons
Used to adjust (increasing/decreasing) temperature settings in 1°C/2°F (or 1°F) increments in a range
of 16°C/60°F to 30°C/86°F.
TIMER setting in a range of 0~24hrs.
NOTE
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.
4. Display
Shows the set temperature in °C or °F and the Auto-timer settings. While on DRY and FAN modes, it
shows the room temperature.
Shows Error codes and protection code:
EH60-Room temperature sensor error.
EH61-Evaporator temperature sensor error.
EC52-Condenser temperature sensor error (on some models).
EH0b-Display panel communication error.
ELOC-Refrigerant leakage detection malfunction (on some models).
P1-Bottom tray is full. Connect the drain hose and drain the collected water. If the P1 code does not erase, call for
service.
NOTE
When one of the above malfunctions occurs, turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact
the manufacturer, its service agents or a similar qualified person for service.
5.Timer button
Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the + & -
buttons. The timer on/off indicator light illuminates under the timer on/off settings.
6. SWING mode
Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can stop the
louver at the desired angle.
7. Continuous Fan function
In Cool or Dry mode, press and hold the constant Fan button for 3 seconds to turn the constant fan
function on or off. When the function is turned on, the constant fan light will illuminate. When the
function is turned on,the constant fan light will turn off
8. SLEEP mode
Press this button, the selected temperature will increase(cooling) or decrease(heating) by 1°C/2°F(or 1°F) 30
minutes. The temperature will then increase (cooling) or decrease (heating) by another 1°C/2°F(or 1°F) after
an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the
originally selected temperature. This ends the Sleep/Eco mode and the unit will continue to operate as
originally programmed.
NOTE: This feature is unavailabe under FAN or DRY mode.
9. Other features
COMFORT SENSE feature
This feature can be activated from the remote control ONLY. There is no indicator light on the control
panel. The remote control serves as a remote thermostat allowing for the precise temperature control
at its location.
To activate the Comfort Sense feature, point the remote control towards the unit and press the Comfort
Sense
button. The remote control will send this signal to the AC until press the Comfort Sense
again.
If the unit does not receive the Comfort Sense signal during any 7 minutes interval, the unit will
exit the
Comfort Sense
NOTE: This feature is unavailabe under FAN or DRY mode.