Sony HCD-SB500W Service Manual page 22

Super audio cd/dvd receiver
Table of Contents

Advertisement

HCD-SB500W
4. Emergency History
On the Test Mode Menu screen, selecting [4] displays the
information such as servo emergency history.
The history information from last 1 up to 10 can be scrolled with
the O key or o key. Also, specific information can be displayed
by directly entering that number with ten keys.
### EMG. History ###
Laser Hours
a.
bb xx xx xx xx xx xx xx
xx xx xx xx xx xx xx xx
a.
bb xx xx xx xx xx xx xx
xx xx xx xx xx xx xx xx
Select:1-9
(1.Latest EMG.)
xxxxhxxm : The laser on total hours. Data below minutes are
omitted.
a.
: Error number.
bb
: Error code.
xx
: Not used.
• Clearing History Information
Clearing laser hours:
Press the [DVD DISPLAY] and [CLEAR] keys in this order.
Then both CD and DVD data are cleared.
Clearing emergency history:
Press the [DVD TOP MENU] and [CLEAR] keys in this order.
Initializing EEPROM data:
Press [DVD MENU] and [CLEAR] keys in this order.
The data have been initialized when "EEPROM Initialize
Finished." message is displayed, press the [RETURN] key to return
to the EMG. History screen.
• Code list of Emergency History
10: Communication to RF amplifier (IC001) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Check sum error of EEPROM (IC204).
14: Communication to servo DSP (IC509) failed, or servo DSP
(IC509) is faulty.
15: Communication to DVD decoder (IC701) failed, or DVD
decoder (IC701) is faulty.
16: Communication to DSD decoder (IC801) failed, or DSD
decoder (IC801) is faulty.
20: Initialization of sled servo failed. It is not placed in the initial
position.
23: Sled servo operation error.
24: Made a request to move the sled servo to wrong position.
30: Tracking balance adjustment error.
31: Tracking gain adjustment error.
33: Focus bias adjustment error.
34: Focus gain adjustment error.
35: Equalizer adjustment error.
40: Focus servo does not operate.
41: With a DVD dual layer disc, focus jump failed.
50: CLV (spindle) servo does not operate.
51: Spindle does not stop.
60: Made a request to seek nonexistent address.
61: Seek error of retry more than regulated times.
70: Control data could not be read.
80: Disc reading failed.
22
CD
xxxxhxxm
DVD
xxxxhxxm
Scroll:UP/DOWN
Exit: RETURN
5. Mecha Error History
On the Test Mode Menu screen, selecting [5] displays the
information of mechanism deck error history.
The history information from last 1 up to 8 can be scrolled with
the O key or o key.
### Mecha Error History ###
1. aa bb cc dd ee xx xx xx
2. aa bb cc dd ee xx xx xx
3. aa bb cc dd ee xx xx xx
4. aa bb cc dd ee xx xx xx
5. aa bb cc dd ee xx xx xx
6. aa bb cc dd ee xx xx xx
7. aa bb cc dd ee xx xx xx
8. aa bb cc dd ee xx xx xx
(1.Latest Err.)
aa : Initialization is completed or not.
FF
: Complete the initializing. (normal operation)
11
: Stocker movement (to chucking position) fail-
ing in the midst of initializing the mechanism
deck.
12
: Stocker movement (to chucking position) fail-
ing in the midst of initializing the mechanism
deck.
1x
: Initializing the mechanism deck.
2x
: Initializing the mechanism deck.
3x
: Initializing the mechanism deck.
41
: Disc eject failing in the midst of initializing
the mechanism deck.
4x
: Initializing the mechanism deck.
50
: Disc eject failing in the midst of initializing
the mechanism deck.
5x
: Initializing the mechanism deck.
A2
: Disc eject failing in the midst of initializing
the mechanism deck.
Ax
: Initializing the mechanism deck.
D3
: Disc eject failing in the midst of initializing
the mechanism deck.
Dx
: Initializing the mechanism deck.
Ex
: Initializing the mechanism deck.
bb : Operating status of mechanism deck at an error occurred.
(lod sq jcp)
00
: Initializing.
10 to 15
: Open operating.
16 to 19
: Kicking cause open failed.
1A to 1F : Open operating.
20 to 27
: Complete the open operation.
28
: No disc and complete the open operation.
29 to 2F
: Complete the open operation.
30 to 3F
: Close requesting.
40 to 4F
: Open requesting.
50 to 5F
: Close operating.
60 to 6F
: Complete the chucking operation.
80 to 8F
: Complete the release operation.
(BU is home position)
90 to 9F
: BU down operating.
A0 to AF : Opening/closing the shutter. Or stationary state
in open/close the shutter is enablement.
B0 to BF : BU up requesting.
C0 to CF : BU down requesting.
D0 to DF : BU upping.
E0 to EF : No disc checking in disc loading.
Scroll:UP/DOWN
Exit: RETURN

Advertisement

Table of Contents
loading

Table of Contents