Measurements
Measurement between
V
and Sig
4 (green and red)
+
+
V- and Sig
(green and white)
+
V
and Sig- (red and black)
+
V
and Sig- (white and black)
-
Sig
/Sig-/V
/V- and aluminium
+
+
body of the load cell
Table 2: Resistance of Flintec / Kogean Planar Beam / --Wing load cell [376|378|284|285]
Measurement between
V
and Sig
4 (green and red)
+
+
V- and Sig
(green and white)
+
V
and Sig- (red and black)
+
V
and Sig- (white and black)
-
Sig
/Sig-/V
/V- and aluminium
+
+
body of the load cell
The relevant cabling diagram shows the designations and associated cable
colour. The measured values only have a limited informative value, however, as
even a defective load cell can supply absolutely correct values when no load is
placed on it. If the load cell supplies incorrect values when unloaded, it is
definitely defective.
05.10.12/RLEU/ARI/MRE
Ohmic resistance [Ω]
Ohmic resistance [Ω]
Table 3: Resistance of VCARE [374]
26/38
~ 800-850
~ 800-850
~ 800-850
~ 800-850
> 500 M
~840
~840
~840
~840
> 500 M