Article number
Number of safety inputs
Digital outputs
Number of digital outputs
Number of safety outputs
Encoder
Connectable encoders
•
•
Interfaces
Number of industrial Ethernet interfaces
Number of PROFINET interfaces
Standards, approvals, certificates
CE mark
CSA approval
UL approval
cULus
FM approval
RCM (formerly C-TICK)
KC approval
EAC (formerly Gost-R)
RoHS conformity
China RoHS compliance
Ambient conditions
Ambient temperature during operation
•
•
Ambient temperature during storage/transpor‐
tation
•
•
Relative humidity
•
•
Vibrations
•
•
Shock testing
•
Cables
Cable length for motor, shielded, max.
Connection method
PDC1000 Drive Controller
Equipment Manual, 12/2023, A5E48775040-AD
Incremental encoder (symmetrical)
Absolute encoder (SSI)
min.
max.
Storage, min.
Storage, max.
Operation, max.
Storage, max.
Vibration resistance during operation acc. to
IEC 60068-2-6
Vibration resistance during storage acc. to
IEC 60068-2-6
Shock resistance during operation acc. to IEC
60068-2-27
Technical specifications
5.1 Technical specifications
6BK1630-1BA00-0AA0
0
2; 24 V DC, 1 A
0
Yes; Up to 200 kHz
Yes; With SSI interface
0
2
Yes
No
No
No
No
No
No
Yes
Yes
No
-20 °C
60 °C
-20 °C
80 °C
90 %; no condensation
95 %; no condensation
5 ... 8.5 Hz / 3.5 mm, 8.5 ... 150 Hz / 1 g; for wall
mounting: 9 ... 29 Hz / 1.5 mm, 29 ... 200 Hz / 5 g
5 ... 9 Hz / 3.5 mm, 9 ... 500 Hz / 1 g
15 g / 11 ms; for wall mounting: 10 g / 30 ms, 25 g /
6 ms
10 m
37