GAS CONNECTION

WARNING
DO NOT USE AN OPEN FLAME WHEN
CHECKING FOR LEAKS!
Leak testing of the appliance shall be conducted according
to the manufacturer's instructions. Before placing the oven
into operation, always check for leaks with soapy water
solution or other acceptable method.
Check for gas leakage with soapy water solution or other
acceptable methods in all gas connections installed
between inlet gas pipe of the appliance, gas regulator, till to
the manual shut-off valve.
All gas connections must comply with national and local
codes. The gas supply line (service) must be the same size
or greater than the inlet line of the appliance. This range
uses a 1/2" NPT inlet (see drawing below for details of gas
connection). On all pipe joints use appropriate sealant
resistant to gas to joint the adapter to range manifold use
only the blue gasket supplied.
If necessary, the appliance must be converted by the dealer,
by a factory-trained professional or by a qualified licensed
plumber or gas service company.
Gas conversion is important for safe and effective use of
the appliance. It is the responsibility of the dealer and the
owner of the range to perform the appropriate gas
conversion following the directions of the manufacturer.
THE GAS CONVERSION PROCEDURE IS DESCRIBED
IN THIS MANUAL AND IN THE PACKAGE CONTAINING
THE CONVERSION NOZZLES SHIPPED WITH EVERY
RANGE.
Please provide the service person with this manual before
work is started on the range.

MANUAL SHUT-OFF VALVE

THIS VALVE IS NOT SHIPPED WITH THE APPLIANCE
AND MUST BE SUPPLIED BY THE INSTALLER.
The manual shut-off valve must be installed in the gas
service line between the gas hook-up on the wall and the
appliance inlet, in a position where it can be reached
quickly in the event of an emergency.
In Massachusetts:
A 'T' handle type manual gas valve must be installed in the
gas supply line to this appliance.

FLEXIBLE CONNECTIONS

In case of installation with flexible couplings and/ or quick-
disconnect fittings, the installer must use a heavy-duty,
AGA design-certified commercial flexible connector of at
least 1/2" (1.3 cm) ID NPT (with suitable strain reliefs) in
compliance with ANSI Z21.41 and Z21.69 standards.
In Massachusetts:
The unit must be installed with a 36" (3-foot) long flexible
gas connector.
In Canada:
Use CAN 1-6.10-88 metal connectors for gas appliances
and CAN 1-6.9 M79 quick disconnect device for use with
gas fuel.

PRESSURE TEST-POINT STOPPER VALVE

To avoid gas leaks, the pressure test-point stopper valve
and gasket supplied with the range must be installed on the
gas fitting at the back of the range according to the diagram
below.
1) Gas Pipe
2) Gasket
3) Gas connection adaptor 1/2" npt with pressure test point
1/8" npt (to be fixed toward external side of the
appliance)
4) Pressure test-point
1
2
3
4
Fig. 8
19