Lift function
The Lift Control function consists of the ability to interact with the lift system through calls and
commands from the DES IP video door entry system.
The operating mode of the lift depends on its control system (BTicino cannot operate the lift but
only send commands, which are interpreted and executed).
Safety must be guaranteed by an access control system or by the lift itself.
The lift control function can be realised in two modes:
–
The first is through protocol commands on RS485.
Using the interface 375010, the IP DES video door entry system sends commands to the lift
control centre to simulate a lift call.
For more information, see the "Lift Interface Software Manual, item 375010".
–
The second mode is through dry contact commands.
The DES IP video door entry system opens and/or closes contacts (output contacts from
interface 375013). Lift calls are simulated when these contacts (correctly connected to the lift
system) are opened or closed.
Interface 375013 must be added as a device in the Community.
After this, it will be necessary to configure the parameters in the
You can see some examples of connection diagrams in the manuals of the IP devices.
Fire-fighting
Enables the door lock opening function in case of fire.
The Fire-fighting function allows the automatic opening of EP door locks in the event of a fire.
The use of this function requires a clean contact in the GND FIRE-FIGHTING input clamp from the
fire fighting system.
It is necessary to enable the function in Settings
OnVif IP cameras
OnVif IP cameras wired on the same network as the IP video door entry system with video
surveillance of public and/or private areas.
Small Entrance Panel
9
User and installation manual
Lift Control function
page.