Circuit Descriptions, Abbreviation List, and IC Data Sheets
9.2.5
42" PSU (LIPS250PS05)
Control Signals
The control/output signals are driven by open collector/open
drain type circuits. The drive requirements are 3V3 Logic. Open
Collector: 2.2 kohms pull up resistor to +3V3.
Signal Levels:
Low or open: less than 0.4V.
High: more than 2.4V.
The Power Supply Unit is controlled via a digital input "Standby
# (Stdby)" and the "BL_ON-OFF" signal at the secondary side.
Table 9-12 Mode of operation
Standby# BL_ON-OFF
3V3
CN7 pin 5
High
Low
ON
Low
Low
ON
Low
High
ON
Output Specifications
Table 9-13 "Standby #" is "low" (ON mode)
Description
Vo1
Symbol
3V3 stdby
Nominal voltage
3.3V
± 3%
Voltage tol.
Min. Current (A)
0
Nom. Current (A)
0.2
Max. Current (A)
0.2
Peak Current (A)
0.5
Ripple and noise
50mV
Ground
GND1
Table 9-14 "Standby #" is "low" (Semi-standby mode)
Description
Vo1
Symbol
3V3 stdby 12Vssb + Vaudio
Nominal voltage
3.3V
± 3%
Voltage tol.
Min. Current (A)
0
Nom. Current (A) 0.2
Max. Current (A) 0.2
Peak Current
0.5
Table 9-15 "Standby #" is "high" (Standby mode)
Description
Vo1
Symbol
3V3 stdby 12Vssb + Vaudio
Nominal voltage 3.3V
± 3%
Voltage tol.
Min. Current (A) 0
Nom. Current
0.015
12Vssb Vaudio HV
Note
OFF
OFF
OFF
Standby
ON
ON
OFF
Semi-standby
ON
ON
ON
ON
Vo2
Vo3
Vo4
12Vssb
+ Vaudio
- Vaudio
12V
+ 12V
- 12V
± 5%
-5%, +10%
-5%, +10%
0.1
0
0
3.4
0.45
0.45
3.4
2.5
2.5
4
2.5
2.5
100mV
100mV
100mV
GND1
GND2 (isolated gnd)
Vo2
Vo3
Vo4
Vo5
- Vaudio
HV
12V
+ 12V
- 12V
0
± 5%
11.4~17V
-11.4 ~ -17V 0
0.1
0
0
0
3.4
0
0
0
3.4
0
0
0
4
0
0
0
Vo2
Vo3
Vo4
Vo5
- Vaudio
HV
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Q522.3E LA
Start-up Sequence
Note: ΔVo/dt ~350V/s (max)
Note: Standby # is from small signal board (SSB).
Figure 9-5 Timings 42"
Protections
3V3 stdby output
Short-circuit proof with auto restart.
Over voltage protection should operate within 120% ~
140% of nominal value.
12Vssb
Short circuit protection with current limit or fuse.
Over voltage protection should operate within 120% ~
140% of nominal value.
Vaudio
Short circuit protection with current limit or fuse.
Over voltage protection should be less than absolute
value 19V.
HV output
Arcing protection.
Short circuit protection.
Over voltage protection should operate when more
than 4 lamps are disconnected.
Table 9-16 Output connectors
Pin
CN2
CN3
1319
1316
1
HVL
HVR
2
HVL
HVR
3
n.c.
n.c.
4
-
-
5
-
-
-
-
6
7
-
-
8
-
-
-
-
9
10
-
-
11
-
-
9.
EN 105
I_18300_082.ep
161008
CN6
CN7
1M95
1M99
3.3VSB
12V
PSON
12V
GND1
GND1
GND1
GND1
GND1
BL-ON
12V
BL-DIM
12V
BOOST
12V
GND1
+12Vaudio
-
GND2
-
-12Vaudio
-

Advertisement