Advanced Settings - Barco R90501001 User Manual

Hide thumbs Also See for R90501001:
Table of Contents

Advertisement

4. To change a setting, use the ▲ or ▼ key to select and press ENTER.
The corresponding adjustment box is displayed. E.g. Horizontal total pixels.
Image 9-66
5. Use the ▲ or ▼ key (or ◄ or ► key) to change the value.
6. Press ENTER to activate the new value.
7. If necessary to change other settings, repeat from step 4.
9.5.2

Advanced settings

About the advanced settings
Clamp delay
The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255.
Clamp width
The width of the clamp pulse can be any value between 0 and 255.
Sync
pulse
Clamp
pulse
Image 9-67
Field polarity
The field polarity function is used for interlaced images. Both rasters of the image could be shifted in
a wrong way (double lines are visible in the image). This can be corrected by forcing the field polarity
to [neg] or [pos].
How to change the clamp delay - clamp width?
1. Press MENU to activate the menus.
2. Use the ▲ or ▼ key to select Image and press ENTER.
3. Use the ▲ or ▼ key to select Timings and press ENTER.
4. Use the ▲ or ▼ key to select Advanced settings and press ENTER.
The Advanced settings menu is displayed.
5. Use the ▲ or ▼ key to select Clamp delay or Clamp width and press ENTER.
A progress bar appears.
6. Use the ▲ or ▼ key to change the setting.
R59770021 CLM R10+ 12/07/2007