Security Function Ver. 1.01 Feb. 2017
NOTE
• USB memory must be connected with the main power switch off.
5. Turn ON the main power switch while pressing the Stop key.
NOTE
• When [Administrator Settings] → [Security Settings] → [USB Connection Permis-
sion setting] → [External Memory (Service)] → [FW Update] is set to "Restrict", a
message "It is limited by the administrator." will appear, and update of the firm-
ware cannot be executed.
• When [Administrator Settings] → [Security Settings] → [FW Update (USB) Perm.
Sett.] is set to "Password Priority", it requires to input a password after confirming
with the administrator.
6. Firmware Update selection screen is displayed.
NOTE
• Unless one of the keys on the control panel is pressed, firmware is automatically
updated after 30 seconds when the main power switch is turned on.
• Selectable items displayed change depending on equipped options, etc.
7. Control panel shows F/W items to be updated, and select the particular type of F/W to
be updated. (Select [YES].)
NOTE
• When a plurality of firmware is stored in a USB memory, touch [FW Data Select] to
select firmware. In the data selection screen, * is added to the firmware data name
in "FW****" folder contained in the USB memory.
• When the BootRom file is in the firmware data, [BootRom] key is displayed. Press
the key to update.
• If either or both of the SCB file and power sub CPU file are contained in the firm-
ware data, [Other FW Update] key is displayed. Press the key to update.
8. Touch the [Language Select].
40
10. Firmware rewriting