Molded Terminal Models
(Not Approved by UL, CSA, or EN)
Use of the molded terminal model is recommended in locations
subject to excessive dust, oil drips, or moisture.
All types of ZC Switches can be fabricated into a molded terminal
version. In this case, the molded terminal model will have the same
dimensions and operating characteristics as the basic model from
which the molded terminal model is fabricated.
Suffix by Location of Lead Outlet
Model (Suffix)
Location of
lead output
COM, NC, NO
Right-hand
-MR
Left-hand
-ML
Underside
-MD
Lead Supplies
Nominal
Speci-
cross-sectional
Leads
fica-
area
tion
(mm
2
)
V.C.T.
(vinyl
3 conductor:
1.25
cabtire
cable)
Note: When placing your order for the Switch, specify the required length of
V.C.T. cable in addition to the model number of the Switch.
Consult with your OMRON representative for other types of lead wires
and for lead wires longer than 3 m.
How to Order
Example:
Standard type:
ZC-Q2255
Location of lead output:Right side
Length of lead:
1 m (V.C.T. lead)
When placing your order for the above Switch, specify the model
number as ZC-Q2255-MR VCT 1M.
http://www.ia.omron.com/
Note: The suffixes on the
left can be added to
the model numbers
given on page 1 to
specify molded
terminals.
External
Terminal
Length
diameter
connec-
(m)
(mm)
tions
Black:
COM
1, 3
10.5 dia.
White: NO
Red: NC
Terminal Protective Cover, Seal Rubber, and
Rubber Packing
(The Switch is equipped with these 3 items as a
standard.)
• ZC Terminal Cover
(Product code: ZC55-0002H)
• ZC Seal Rubber
(Product code: SC-1404C)
• ZC Rubber Packing
(Product code: ZC55-0003F)