Connectivity - Energy state

The sub menu 'Energy state' can be used to influence the heat pumps's operation based on
availability of renewable energy - for instance from PV-panels.
There are two options to make use of this logic:
- Use Modbus: LG Energy Storage System (ESS) or another third-party device is connected by
Modbus serial line.
- Use Digital inputs: A third-party controller (e.g. SmartHome controller or PV inverter) is
connected through 230 V inputs ("SG-Ready contacts").
Using Modbus RTU allows to use eight different energy states, while Digital inputs provides four
different energy states.
Digital inputs (TB_SG)
ES1
Close
Open
Open
Close
-
-
-
-
NOTE
Use setting 'Digital inputs assignment' to replace Energy state 3 and/or 4 with any of Energy
states 3~8.
Energy state
ES2
Open
1
Open
2
Close
3
Close
4
-
5
-
6
-
7
-
8
INSTALLER SETTING
Mode
Default
Heating
Off
Cooling
Off
DHW
Off
Heating
Normal
Cooling
Normal
DHW
Normal
Heating
2
Cooling
+/- 0
DHW
5
Heating
+/- 0
Cooling
+/- 0
DHW
Target: 80°C
Heating
5
Cooling
-5
DHW
30
Heating
2
Cooling
-2
DHW
10
Heating
-2
Cooling
2
DHW
+/- 0
Heating
-5
Cooling
5
DHW
+/- 0
163
Range
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
0 ~ +30
-30 ~ 0
0 ~ +50
0 ~ +30
-30 ~ 0
0 ~ +50
-30 ~ 0
0 ~ +30
-50 ~ 0
-30 ~ 0
0 ~ +30
-50 ~ 0