Annex - LG HM121HF UB60 Installation Manual

Air-to-water heat pump
Hide thumbs Also See for HM121HF UB60:
Table of Contents

Advertisement

ANNEX

174
ANNEX
NOTE
The sensor resistance value and the voltage value at both ends may vary depending on the
ambient temperature and the value has a deviation of 5 %.
There may be some errors depending on the measurement equipment.
Room air temperature sensors (NTC 10kOhm)
Indoor Temp.(°C)
-10 °C
-5 °C
0 °C
5 °C
10 °C
15 °C
20 °C
25 °C
30 °C
35 °C
40 °C
45 °C
Pipe temperature sensors (NTC 5 kOhm)
Indoor Temp.(°C)
-10 °C
-5 °C
0 °C
5 °C
10 °C
15 °C
20 °C
25 °C
30 °C
35 °C
40 °C
45 °C
50 °C
55 °C
60 °C
65 °C
Resistance(kΩ)
60 kΩ
44 kΩ
33 kΩ
25 kΩ
0 kΩ
15 kΩ
12 kΩ
10 kΩ
8 kΩ
6 kΩ
5 kΩ
4 kΩ
Resistance(kΩ)
29 kΩ
22 kΩ
17 kΩ
13 kΩ
10 kΩ
8 kΩ
6 kΩ
5 kΩ
4 kΩ
3.2 kΩ
2.6 kΩ
2.1 kΩ
1.7 kΩ
1.4 kΩ
1.2 kΩ
1 kΩ
Voltage(V)
4.1 V
3.9 V
3.6 V
3.4 V
3.1 V
2.8 V
2.5 V
2.2 V
1.9 V
1.6 V
1.5 V
1.3 V
Voltage(V)
4.1 V
3.9 V
3.6 V
3.3 V
3 V
2.8 V
2.5 V
2.2 V
1.9 V
1.7 V
1.5 V
1.2 V
1 V
0.9 V
0.8 V
0.7 V

Advertisement

Table of Contents
loading