Installation work and electrical wiring
must be carried out by qualified
persons in accordance with all
applicable regulations and standards,
including the design of the equipment.
Do not exhaust air into a flue from
other appliances that burn gas or other
fuels.
The regulations regarding exhaust air
flow must be met.
The extractor hood must be installed
at a minimum distance of 65 cm above
the cooking surface of a hob.
The extractor hood must be installed
at a maximum distance of 75 cm above
the cooking surface of a hob.
30
Installation in the cupboard
Drill one 130 mm diameter hole and four 3.5 mm diameter holes as shown
below.
ATTENTION: If your extractor hood is running in recirculation mode, it is
not necessary to drill a 130 mm diameter hole.
Use the 4 screws to attach the cooker hood to a kitchen cabinet. Check that
the screws are correctly seated by temporarily securing the cooker hood. Once
properly installed, attach the hood and tighten the screws if necessary.