DW/P
Mounting
ba77278e01
NOTE
The DW/P drinking water panel may only be installed in closed, frost-free rooms.
Other requirements for the mounting location:
 Free wall (at least 850 x 700 mm, see figure 3-1)
 Distance under the drinking water panel
Recommendation: approx. 50 cm
 Distance of the drinking water panel from the wall:
Recommendation: 40 mm
(Long cables can be tidied up behind the drinking water panel.)
Spacers: See section 3.1 S
 Do not place or operate any water-sensitive devices below the
drinking water panel.
CAUTION
Risk of injury when transporting heavy loads.
Wear safety shoes for transport, installation and mounting
work (see section 2.4 Personal protective equipment (PPE)).
Transport the drinking water panel with two people.
1.
Select an easily accessible mounting location for the drinking water
panel.
2.
Drill holes at the correct distances (see figure 3-1) in the wall intended
for mounting.
3.
Select 4 screws:
 suitable for the material of the wall
 suitable diameter (8 mm)
for the spacers
 suitable length (approx. 10 cm)
(Recommendation: 40 mm distance from the wall)
4.
Insert the screws through the holes in the drinking water panel.
5.
Place two spacers on each screw.
The spacers are included in the scope of delivery.
One spacer is 20 mm long.
The spacers are suitable for screws with a diameter of 8 mm.
01/2024
.
COPE OF DELIVERY
Installation
17